Control Module Familiarization
Become familiar with the various controls and connectors on the Control Module before connecting to power source. Refer to
illustrations and numbered items below for brief description.
1.
Wire speed control potentiometer for varying wire feed speed
2.
Preflow timer (0-1 second) adjusts wire feeder start-up
delay time from when gas flow starts
3.
2A circuit breaker, manual reset; protects control circuitry
4.
Output connector for spool gun electrode cable
5.
Connector for spool gun control cable
6.
Gas fitting for spool gun gas line
7.
Carrying handle
8.
Connector for input cable assembly control cable to power
source
9.
Input connector for input cable assembly electrode cable
10.
Lockout bar for mode switch
11.
Mode switch for selecting type of contactor circuit in power
source
12.
Gas fitting for input cable assembly gas line
13.
Control Module code and serial numbers
-11-
Unpacking The SG Control Module
Carefully unpack the Control Module and make sure you have
the following contents:
Control Module
Operating Manual