TABLE B.5 - MAGNUM PRO CURVE 200 FM 

200 AMP @ 60% DUTY CYCLE WITH CO2 GAS 

150 AMP @ 60% DUTY CYCLE WITH MIXED GAS 

Product 
Number 

Gun Cable 

Length (m) 

Wire Size in. 

(mm) 

Contact Tips 

Standard Duty 

Gas Diffuser 

Assembly 

 

Gas Nozzle 

 

Insulator 

 

Cable Liner 

 

Gun Tube 60° 

K2950-2- 

FM-45 

15 FT. (4.5) 

.035 (0.9) 
.045 (1.2) 

KP2744-035 
KP2744-045 

KP2746-1 

KP2742-1- 

62R 

KP2773-2  KP42-4045-15  KP2924-60 

 

TABLE B.6 - MAGNUM PRO CURVE 300 FM 

300 AMP @ 60% DUTY CYCLE WITH CO2 GAS 

200 AMP @ 60% DUTY CYCLE WITH MIXED GAS 

Product 
Number 

Gun Cable 

Length (m) 

Wire Size in. 

(mm) 

Contact Tips 

Standard Duty 

Gas Diffuser 

Assembly 

 

Gas Nozzle 

 

Insulator 

 

Cable Liner 

 

Gun Tube 60° 

K2951-2- 

FM-45 

15 FT. (4.5) 

.035 (0.9) 
.045 (1.2) 

KP2744-035 
KP2744-045 

KP2746-1 

KP2742-1- 

62R 

KP2773-2  KP44-3545-15  KP2924-60 

 

TABLE B.7 - MAGNUM PRO CURVE 400 FM 

400 AMP @ 60% DUTY CYCLE WITH CO2 GAS 

400 AMP @ 50% DUTY CYCLE WITH MIXED GAS 

Product 
Number 

Gun Cable 

Length (m) 

Wire Size in. 

(mm) 

Contact Tips 

Standard Duty 

Gas Diffuser 

Assembly 

 

Gas Nozzle 

 

Insulator 

 

Cable Liner 

 

Gun Tube 60° 

K2952-2- 

FM-45 

15 FT. (4.5) 

.035 (0.9) 
.045 (1.2) 

KP2744-035 
KP2744-045 

KP2746-1 

KP2742-1- 

62R 

KP2773-2  KP44-3545-15  KP2924-60 

Summary of Contents for K1723-1

Page 1: ...3 K2950 2 FM 45 K2951 2 FM 45 K2952 2 FM 45 Register your machine www lincolnelectric com register Authorized Service and Distributor Locator www lincolnelectric com locator Save for future reference...

Page 2: ...and the general area IN A LARGE ROOM OR OUTDOORS natural ventilation may be adequateifyoukeepyourheadoutofthefumes Seebelow USENATURALDRAFTSorfanstokeepthefumesaway from your face Ifyoudevelopunusuals...

Page 3: ...rformrequiredmaintenance Removeguardsonlywhen necessary and replace them when the maintenance requiring theirremovaliscomplete Alwaysusethegreatestcarewhen working near movingparts 1 f Donotputyourhan...

Page 4: ...when welding or observingopenarcwelding Headshield andfilterlensshould conform to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material toprotectyourskinandthatofy...

Page 5: ...ftheweldingcurrentpassingthroughliftingchains cranecablesorotheralternatecircuits Thiscancreatefire hazardsoroverheatliftingchainsorcablesuntiltheyfail 6 h Also see item1 c 6 I ReadandfollowNFPA51B St...

Page 6: ...1 AVOIDING FEEDING PROBLEMS B 1 PRODUCT NUMBERS TABLE B 1 MAINTENANCE SECTION D REMOVAL INSTALLATION AND TRIMMING INSTRUCTIONS FOR LINERS D 1 GUN TUBES AND NOZZLES D 1 GUN CABLES D 3 TROUBLESHOOTING...

Page 7: ...ableintothematingconnectorontheoutgoingsideofthe feeder wire drive Secure the cable connection by snuggling the Fast Mate connector collar nut LINER INSTALLATION NOTE FM models using Fast Mate connect...

Page 8: ...ortheGMAWprocessandOS70orOS71 LincolnOutershield coredelectrodes forthegas shieldedFCAW process ELEcTRODES AND EQUIpMENT TheMAGNUM 200FMgunandcablehasbeendesignedforuse withLincolnL 50andL 56 solidste...

Page 9: ...5 1 2 KP14 45 KP54A KP24A 62 KP34A KP44 3545 25 KP1928 1 K479 14 25FT 7 6 052 1 3 1 16 1 6 KP14 116 KP54A KP24A 62 KP34A KP44 116 25 KP1928 1 TABLE B 3 MAGNUM 400 FM DUAL SCHEDULE 400 AMP 60 DUTY CYCL...

Page 10: ...O2 GAS 200 AMP 60 DUTY CYCLE WITH MIXED GAS Product Number Gun Cable Length m WireSizein mm Contact Tips Standard Duty Gas Diffuser Assembly Gas Nozzle Insulator Cable Liner GunTube60 K2951 2 FM 45 15...

Page 11: ...sed e Fully seat the liner bushing into the connector Finger tighten the liner nut onto the cable connector f Withthecablestraight trimlinerto1 1 4 31 8mm Removeanyburrsfromtheendoftheliner g Screwthe...

Page 12: ...FAST MATE GUNS SERIES MAINTENANCE D 2 FIGURE D 1 MAGNUM FIGURE D 2 MAGNUM PRO FIGURE D 3 GUN TUBE ASSEMBLY 9 16 14 3mm LINER TRIM LENGTH INSULATOR DIFFUSER CONTACT TIP NOZZLE ASSEMBLY...

Page 13: ...tresults inserta 175 197 4 5 5 0mm diameterrodthroughtheconnectorandintocoreof cable approximately 5 00 127 mm when pushing the connector tube into the cable core tube Totighten hold theconnectorinpla...

Page 14: ...leroutingstothesocketsonthebackside oftheconnector Assembletheincomingconnectortothe cablebyforcingthesteeltubeoftheconnectorintotheinside diameterofthecableinnertubeuntilthecopperstrandsare buttedaga...

Page 15: ...an kill Donottouchelectricallylivepartssuchasoutputterminals or internal wiring NOTE If the cable handle becomes difficult to slide over connection try rotatingit m Install and trim liner per Removal...

Page 16: ...FAST MATE GUNS SERIES MAINTENANCE D 6 FIGURE D 8 FIGURE D 9 FIGURE D 10...

Page 17: ...ed below Step 1 LOCATE PROBLEM SYMPTOM Look under the column labeled PROBLEM SYMPTOMS This columndescribespossiblesymptomsthatthemachinemay exhibit Findthelistingthatbestdescribesthesymptomthatthe mac...

Page 18: ...rode connections c Be sure the following connections are tight electrodecabletowirefeederandpowersource workcabletopowersourceandwork guncableto wirefeedercontactblock gunnozzletobodyand contact tip t...

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ...e sich von den Elektroden unddem Erdboden lEntfernenSiebrennbarresMaterial lTragenSieAugen Ohren undK r perschutz Portuguese ATEN O lN o toque partes el tricaseelec trodos com a pele ou roupa molha da...

Page 23: ...op rezpasavec les panneaux ouverts ou avecles dispositifs de protection enlev s French ATTENTION lVermeidenSiedasEinatmenvon Schweibrauch l SorgenSief rgute Be und Entl ftung des Arbeitsplatzes lStro...

Page 24: ...particular purpose withrespecttosuchinformationoradvice Asamatterof practical consideration we also cannot assume any responsibility forupdatingorcorrectinganysuchinformationoradviceonceit hasbeengive...

Reviews: