English 8 English
24
23
27
29
25
26
Figure 5. Standard view
24
26
27
23
29
28
Figure 6. Advanced view
23. Status Bar.
A
B
C
D
E
F
G
H
Figure 7
A
- A/B Procedure
B
- Information about active welding mode
C
- Trigger torch operating mode (2 step/ 4 step)
D
- USB Memory Connected
E
- Access control is active
F
- Cooler status
G
- MECHAPULSE™ active
H
- Time
24. Measured value of current (Figure 5) and voltage
(Figure 6).
25. Measured value of voltage.
26.
Parameter Value (wire feed speed or current)
regulated by Left Control [21].
27. Parameter Value (voltage, trim) regulated by Right Control
[20].
28. Visualization of Welding Parameters (for synergic
modes only).
29. Welding Parameters Bar.
Welding Parameters Bar
The Welding Parameters Bar enables:
Welding process / program selection.
Gun operating mode selection (2 step/4 step for
GMAW, FCAW, GTAW process).
Add or hide functions and welding parameters – user
setup.
Change the setup.
Table 1 Default GMAW and FCAW Welding
Parameters Bar
Symbol
Description
Welding process / program selection
Support
Trigger torch operating mode (2 step/
4 step)
Pinch
Configuration
User setup
WARNING
Availability of the parameters depend on selected welding
program / welding process.