English 8 English
Table 1 LED Light Conditions
LED Light
Condition
Meaning
Only machines which using CAN
protocol for communication
Steady Green
Correct operation mode. The power
source communicates normally with
all peripheral equipment.
Blinking Green
Occurs during a system reset, and
indicates that the power source is
mapping (identifying) additional
connected components in the system.
This condition occurs for 1-10
seconds after connecting the power
supply or when the system
configuration is changed during
operation.
Alternating
Green and Red
If the status lights are flashing any
combination of red and green color, it
means that an error is present in the
machine.
Each digit of the code represents the
number of red flashes of the indicator
light. Individual code digits are flashed
in red with a long pause between
digits. If more than one code is
present, the codes will be separated
by green light. Read the error code
before you turn of the machine.
To clear the error, turn off the
machine, wait a few seconds, and
then turn on the machine again. If the
error remains, a maintenance is
required. Please contact the nearest
authorized service center or Lincoln
Electric and report the error code.
Steady Red
Indicate no communication in CAN
protocol.
26. LED Indicator: Informs that the left display shows the
wire feed speed.
27. LED Indicator: Informs that the left display shows the
ampere units.
28. LED Indicator: Informs that the right display shows
the volts units.
29. Welding Programs Indicators: LED light indicate the
active manual weld mode. See Table 2.
30. Welding Parameters Indicators: LED light indicate
the active weld parameters. See Table 3.
Welding process change
It is possible to quick recall of one of the six manual
welding programs - Table 2.
Table 2 Manual Weld Modes:
Symbol
LED
Process
GMAW
GMAW MIX
GMAW CO
2
GMAW AR
FCAW
FCAW MIX
FCAW CO
2
SMAW
SMAW
To set the welding process:
Press the left button [23], to select the right weld mode
– LED of the current program flashes.
Again press the left button, the active weld mode
indicator will skip to the next program.
WARNING
During switching the displays show a “dotted line” on the
screen.