English 18 English
Memories
Welding process and all parameters which belongs to
cycle can be saved in a memory slot in order to be
recalled after.
“Memories” menu is accessible for both process TIG and
Stick process from “Home menu”.
Figure 19
Push the right button to access to memories menu.
Figure 20
1. On the top of memory page, the current settings
which are going to be saved are displayed.
2. With the knob it is possible to scroll up or down to
select an empty or used slot memory. If the slot is
already used, the parameters associated to the
backup are displayed.
3. Select “Add New memory” to use an empty slot.
4. Push the knob button to recall the process and
corresponding parameters stored in the selected
slot.
5. In order to save the current setting in memory, push
the right button and keep it hold until the end of
saving.
Figure 21
If button is released before the end of saving process,
slot will not be erased
1
2
3
4
5