background image

 

 

SRT3-10 - Ops Manual 

UTILITY SPECIFICATION 

 

LINCOLN FRONT RETURN TOASTER 

 

Model 

Voltage 

Hz 

Current 

Watts 

Phase 

Belt Width 

Width 

Depth 

Height 

8005-000-U 

(DOMESTIC) 

208 / 240 VAC 

60 Hz 

21.2 Amps 

4400 

10” 

(254mm) 

15” 

(381mm) 

26 ½” 

(673mm) 

16” 

(406mm) 

8005-000-E 

(EXPORT) 

230 / 240 VAC 

50/60 HZ 

21.2 Amps 

4400 

10” 

(254mm) 

15” 

(381mm) 

26 ½” 

(673mm) 

16” 

(406mm) 

NOTE: Specifications subject to change without notice. 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

EXTERIOR DIMENSIONS 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

This toaster must be used with proper voltage as 
specified on the unit data plate located on the 
rear panel of toaster.  Use of any other voltage or 
altering plug will damage unit, void warranty, and 
may cause injury. 

!

 

WARNING! 

!

!

CE UNIT POWER CORD REQUIREMENTS 

 

The standard requires that the supply cord must be oil-
resistant and not lighter than ordinary polychloroprene 
(60245 IEC 57) (IEC/EN 60335-2-48). 

 

Lincoln requires that the power cord must be: 

 

3 x 4.0mm²  90°C 

Summary of Contents for 8005-000-E (EXPORT)

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS for SRT3 10 FRONT RETURN TOASTER MODEL 8005 TO BE SERVICED ONLY BY AUTHORIZED PERSONS SRT3 10ops REV B...

Page 2: ...toasting of these more difficult products Certain breads that contain fruit and nuts may require more attention Loose pieces can fall on the heating elements or into the conveyor mechanism and cause...

Page 3: ...SIONS 4 BEFORE INSTALLATION 5 INSTALLATION 5 ELECTRICAL SERVICE GROUNDING INSTRUCTIONS 5 ELECTRICAL CODE REFERENCE 6 VENTILATION 6 SPACING 6 CONTROL PANEL FEATURES 6 FUNCTIONS 6 OPERATING INSTRUCTIONS...

Page 4: ...E Specifications subject to change without notice EXTERIOR DIMENSIONS This toaster must be used with proper voltage as specified on the unit data plate located on the rear panel of toaster Use of any...

Page 5: ...lowing component Entry Tray is properly installed ELECTRICAL SERVICE GROUNDING INSTRUCTIONS Heat is supplied by ten 10 infrared heating elements with six 6 located on top and four 4 on the bottom Each...

Page 6: ...latest edition SPACING If the unit is placed next to a high heat appliance such as a fryer or grill you must allow at least 1ft 304 8mm distance for proper operation If the toaster is not located nex...

Page 7: ...l Menu Programs on next page for more information 4 For peak operation allow the toaster to warm up for 30 minutes prior to use On Off Switch DANGER Do not work around conveyor belt with long hair loo...

Page 8: ...spective menus Once you have selected the desired menu follow the step by step operating instructions on the following pages to operate your toaster Press and hold the 1 button to operate the toaster...

Page 9: ...ting The allowable range for TIME settings is between 15 and 60 seconds After a few seconds the display will revert back to the previous view 2 To read what the current TEMPERATURE INTENSITY settings...

Page 10: ...then release finger off the Up button 2 While the display is blinking press either the Up or Down buttons depending on the TIME setting you wish to reach 3 Once you have reached the desired TIME sett...

Page 11: ...linking press either the Up or Down buttons depending on the TEMPERATURE INTENSITY setting you wish to reach 3 Once you have reached the desired setting wait for display to stop blinking The new setti...

Page 12: ...f the toaster If the user has entered the calibration menu the display will read 00 Follow these instructions to immediately exit the calibration menu 1 If the display reads 00 you have accidentally e...

Page 13: ...unit CAUTION Toaster must be cool Do not use power cleaning equipment steel wool or wire brushes on stainless steel surfaces CAUTION When using cleaning solutions be sure they meet local and national...

Page 14: ...SRT3 10 Ops Manual 14 SCHEMATIC DOMETIC MODEL 8005 000 U...

Page 15: ...SRT3 10 Ops Manual 15 SCHEMATIC EXPORT MODEL 8005 000 E...

Page 16: ...ciated therein null and void This includes any damage costs or legal actions resulting from the installation of any Lincoln commercial cooking equipment in a non commercial application or installation...

Page 17: ...SRT3 10 Ops Manual 17 This page intentionally left blank...

Page 18: ...SRT3 10 Ops Manual 18 This page intentionally left blank...

Page 19: ...SRT3 10 Ops Manual 19 This page intentionally left blank...

Page 20: ...odservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Telephone 260 459 8200 U S Facsimile 888 790 8193 Int l Facsimile 260 436 0735 Technical Support Hotline...

Reviews: