ELECTRICAL CODE REFERENCE
IN USA
When installed, this appliance must be electrically grounded and its installation must comply with the National
Electric Code, ANSI-NFPA 70, latest version, the Manufacturer’s Installation Instructions, and applicable municipal
building codes.
IN CANADA
All electrical connections are to be made in accordance with CSA C22.1 – Canadian Electrical Code Part 1 and/or
local codes.
ALL OTHER COUNTRIES
Local electrical codes will prevail.
1. Strain Relief is provided with each toaster. International Dealer/Distributors provide applicable power cord/plug
for each customer.
2. All pole disconnection switch 3mm open contact distance.
3. To prevent electrical shock, an equal potential bonding ground lug is provided in the back. This allows the
toaster to be connected to an external bonding system.
VENTILATION
Local codes prevail. These are the “authority having jurisdiction” as stated by the NATIONAL FIRE PROTECTION
ASSOCIATION, INC. in NFPA 96, latest edition.
SPACING
If the unit is placed next to a “high-heat” appliance such as a fryer or grill, you must allow at least 1ft. (304.8mm)
distance for proper operation. If the toaster is not located next to a high-heat appliance, it must have 6” (152mm) of
clearance from all combustible surfaces. If unit is not near a combustible surface, approximately 1” (25.4mm) of
clearance is recommended for proper air circulation.
CONTROL PANEL FEATURES
FUNCTIONS
THERMAL CUT-OUT SWITCH
The Front Return Toaster includes a “safety thermal cut-out switch” for your protection. This safety related device
is designed to insure that the toaster doesn’t overheat and damage the unit. In the unlikely event that the toaster
would exceed the specified operating temperature range, the “safety thermal cut-out switch” will activate, thus
blocking power to the toaster and causing it to turn off.
Set Conveyor Speed
Set Temperature
Display
Set Program Modes
CAUTION:
In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this
appliance must not be supplied through an external switching device, such as a
timer, or be connected to a circuit that is regularly switched on and off by the utility.
!
Summary of Contents for 8005-000-E (EXPORT)
Page 14: ...SRT3 10 Ops Manual 14 SCHEMATIC DOMETIC MODEL 8005 000 U...
Page 15: ...SRT3 10 Ops Manual 15 SCHEMATIC EXPORT MODEL 8005 000 E...
Page 17: ...SRT3 10 Ops Manual 17 This page intentionally left blank...
Page 18: ...SRT3 10 Ops Manual 18 This page intentionally left blank...
Page 19: ...SRT3 10 Ops Manual 19 This page intentionally left blank...