Natural gas CO
2
– 9.5%±0.1 CO ˂20 PPM
Propane gas CO
2
– 10.5%±0.1 CO ˂20 PPM
Butane gas CO
2
– 11.0%±0.1 CO ˂20 PPM
If required, adjustment is made via the venturi
throttle screw after removing the access panel.
Anticlockwise increases the gas making the
mixture
richer
and
increasing
the
CO
2
percentage.
Clockwise decreases the gas making the
mixture leaner and decreasing the CO
2
percentage.
FILTER MODE
HOT OIL
– Wear protective clothing, gloves and safety glasses.
When filtering oil during normal service, set the control knob to the ‘off’
position, wait for at least 5 minutes before draining to allow the unit to cool.
The oil or fat must be in a liquid form before operating the oil pump
Isolate the unit from the gas supply.
Set the thermostat control knob to the off position
.
Ensure the oil suction pipe is secure within the drain tank and that the drain tank is
pushed fully onto the oil inlet pipe.
Ensure the filter bag is within the filter bag frame and correctly aligned in the drain
tank.
Ensure that the stainless drain basket is sitting in the filter bag.
Open the drain valve and allow the oil to drain. Close the drain valve.
Connect the oil return lance to the quick release coupling.
To operate the pump
set the ‘Filter/fryer mode’ toggle switch in filter mode.
The pump will operate for a predetermined time before stopping.
It is normal for a small amount of oil to remain in the bottom of the drain tank.
To stop the pump set
the ‘Filter/Fryer mode’ toggle switch to Fryer mode.
The green neon will light.
This manual together with the user instructions must be kept in a safe and
accessible place for future reference.
Ensure that the person responsible understands how to safely operate, clean and
shut down this appliance and is made aware of the position of the gas isolating
cock, the electrical supply isolation switch in the event of an emergency, the reset
for the limit stat, the burner and the filtration pump.