PREPARATION
Remove all packaging materials and protective coatings prior to installation.
VENTILATION
The area in which this equipment is to be installed should have sufficient fixed ventilation to
comply with local legislation requirements. It is recommended that a room or internal space
be provided with a minimum free area of 4.5cm
2
per kW (3,400Btu/hr) of total heat input.
SITING
The appliance must be installed in accordance with the appropriate regulations listed prior.
It is recommended that this appliance is sited under an extraction canopy for the removal of
combustion products.
The appliance should be installed on a level surface, in a suitable position that is well lit
and draught free, and positioned to minimise the possibility of accidental touching.
A clear space of at least 100mm must be left to the rear of the appliance and 600mm to the
front to allow for safe operation.
Any partitions, walls or kitchen furniture less than 100mm from the appliance must
be of non-combustible materials. Should a flexible hose be used the unit must be
secured to the wall by the use of a chain.
ELECTRICAL SUPPLY AND CONNECTION
If the supply cable is damaged it should be replaced by Lincat Ltd or other suitably qualified
persons, in order to avoid a hazard.
For safety regulations the plug or means of disconnection must always be accessible.
This unit must be earthed.
This unit is supplied with a 13 amp plug. If replacing the plug, connect the terminals as
follows:
Green and yellow wire
Earth
E
Blue wire
Neutral N
Brown wire
Live
L
GAS SUPPLY AND CONNECTION
Check that the gas supply corresponds to that specified on the data plate.
Connection is at the rear of the unit
via a ½” Rp thread. The gas supply tubing or hose shall
comply with the national requirements in force and shall be periodically examined and
replaced as necessary.
An isolating cock should be fitted into the supply line close to the unit for emergency
shutdown or servicing purposes.
If the supply pressure exceeds 37mbar for 3rd family gases then an external regulator
must be fitted at the appliance inlet.
INSTALLATION