IS 583 ECN 3851
Page 5 of 14
This appliance must be earthed.
If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth E
Blue wire Neutral N
Brown wire Live L
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of H 07 RN-F
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
The appliance must be installed at least 50mm from any side walls and 100mm from
any back walls
If the appliance must be fitted near walls, partitions kitchen furniture etc we
recommend they are made from non-inflammable material, otherwise they should be
covered with a suitable heat-resistant material. Full attention must be paid to fire
prevention regulations
The water inlet must be between 50 and 300 kPa.
If this appliance is fitted with castors, use caution at all times when manipulating or
moving, and lock castors when appliance is in position. Drain the appliance BEFORE
moving it.
Earth and equipotential connection
The appliance must be connected to an equipotential system – the terminal is
situated near the entry point of the electrical supply cable and is marked by the
symbol
The appliance must be earthed. Connect the earth cable to the terminal near the
terminal block marked by the symbol
START THE APPLIANCE FOLLOWING THE OPERATING INSTRUCTIONS
Inspection of the electrical supply
Start the appliance following the instructions for use. Check the heating devices are
working correctly.
Raise and lower the tank, dependant on model. Ensure that the cut out operates
when the tank is raised, and that power is restored when the tank is lowered into the
working position again.
In the event of a malfunction, this appliance is equipped with a safety thermostat that
interrupts the supply. After the cause has been identified and rectified, restart the
appliance by resetting the thermostat manually – push the red button situated under
the base at the front left hand side.
If necessary, please consult ‘Potential troubleshooting and solutions’ section.