IS 583 ECN 3851
Page 3 of 14
WARNINGS AND PRECAUTIONS
This appliance must be installed, commissioned, and serviced by a qualified person
in accordance with national and local regulations in force in the country of
installation.
Strip plastic coating and clean the appliance before use.
During operation parts may become hot - avoid accidental contact.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified person.
Ensure that the plug/socket is accessible at all times.
Disconnect this appliance before servicing, maintenance or cleaning.
This appliance should only be used by a qualified adult.
TECHNICAL DATA
Model
OE8802
Height (mm)
900
Width (mm)
900
Depth (mm)
800
Height - Lid Up (mm)
1600
Weight (kg)
184
Total power rating (kW)
12
Supply 1N ~+E
230V 50-60Hz
Current (A)
52.2
Supply 3N~+E
400V 50-60Hz
Current (A)
L1 17.4
L2 17.4
L3 17.4
Thermostat range
Marked 1 to 5 – (Approx. 90-280°C)
Cold water mains
G3/4”
Frequency
50/60Hz