Lincat OE8802 Installation, Operating, Servicing And Conversion Instructions Download Page 3

IS 583   ECN 3851 

Page 3 of 14 

 

 

 

WARNINGS AND PRECAUTIONS

 

 
 

This appliance must be installed, commissioned, and serviced by a qualified person 
in accordance with national and local regulations in force in the country of 
installation. 

 

Strip plastic coating and clean the appliance before use. 
 
During operation parts may become hot - avoid accidental contact. 
 
If the supply cord is damaged, it must be replaced by the manufacturer, its service 
agent or similarly qualified person.  

 

 
Ensure that the plug/socket is accessible at all times.  

 

 
Disconnect this appliance before servicing, maintenance or cleaning. 
 
This appliance should only be used by a qualified adult.

 

 

 
 

TECHNICAL DATA

 

 
 

Model 

OE8802 

Height (mm) 

900 

Width (mm) 

900 

Depth (mm) 

800 

Height - Lid Up (mm) 

1600 

Weight (kg) 

184 

Total power rating (kW) 

12 

Supply 1N ~+E 
230V 50-60Hz 
Current (A) 

52.2 

Supply 3N~+E 
400V 50-60Hz 
Current (A) 

L1  17.4 
L2  17.4 

L3   17.4

 

Thermostat range 

Marked 1 to 5 – (Approx. 90-280°C) 

Cold water mains 

G3/4” 

Frequency 

50/60Hz 

 

Summary of Contents for OE8802

Page 1: ...Electric Heated Tilting Bratt Pan OE8802 Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number __________________________ Dealer _________________________________ _______________________________________ ...

Page 2: ...e Information and Guarantee 16 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that these are understood at all times WARNING This symbol is used whenever there is a risk of personal injury CAUTION This symbol is used whenever there is a risk of damaging your ...

Page 3: ... must be replaced by the manufacturer its service agent or similarly qualified person Ensure that the plug socket is accessible at all times Disconnect this appliance before servicing maintenance or cleaning This appliance should only be used by a qualified adult TECHNICAL DATA Model OE8802 Height mm 900 Width mm 900 Depth mm 800 Height Lid Up mm 1600 Weight kg 184 Total power rating kW 12 Supply ...

Page 4: ...only be used by qualified professionals An equipotential bonding terminal is provided to allow cross bonding with other equipment Install this appliance on a level surface ensuring all air vents are unobstructed Any partitions walls or furniture must be of non combustible material Minimum distances A 50mm B 1000mm see Fig 1 B A A Figure 1 ...

Page 5: ...ted with castors use caution at all times when manipulating or moving and lock castors when appliance is in position Drain the appliance BEFORE moving it Earth and equipotential connection The appliance must be connected to an equipotential system the terminal is situated near the entry point of the electrical supply cable and is marked by the symbol The appliance must be earthed Connect the earth...

Page 6: ...ere reaction in the pan which could cause scolds and burns if done carelessly a b c g f e d Figure 2 Bratt Pan The bratt pan is fitted with control knob see figure 2 power indicator lamp heating indicator lamp a hand wheel for tilting the pan and a button for filling with water The control knob a sets the temperature of the tank and the gas burner ignites automatically when switched to the on posi...

Page 7: ...y be raised or lowered at any time during the cooking cycle To do this lift the lid and turn the hand wheel clockwise on the appliance to raise and empty the tank Turn the wheel counter clockwise to lower the tank Moderate the speed to obtain an even and controlled pour this will vary depending on viscosity of contents Filling the tank with water Caution Ensure the tank is seated correctly in the ...

Page 8: ...hat the lifting mechanism is greased at least every six months Rocol Foodlube Universal 2 This is accessed by lifting the tank which will give access to the lifting screw thread The lid springs should be done at the same time These are accessed by removing the cover located at each end and centrally by screws Do not use a water jet or steam cleaner and do not immerse this appliance Always disconne...

Page 9: ... from the bracket Replace all removed parts in reverse order Amber neon Remove hand wheel Remove facia panel Unscrew the neon and disconnect the wiring Replace all removed parts in reverse order Water valve replacement Remove left hand access cover Disconnect water valve Unscrew and remove from pipe and brackets Replace all removed parts in reverse order Tank position micro switch Remove right han...

Page 10: ...hecking the problem remains switch the appliance off immediately and disconnect it from the power supply Contact the technical support centre Intervention of safety thermostat Thermostat defective Tank lifting micro switch defective Difficult or unsuccessful temperature regulation Defective energy regulator Defective thermostat Difficult or noisy operation of the tank lifting mechanism Poor lubric...

Page 11: ...A145 CASTOR OPUS SWIVEL CO264 SIEMANS CONTACTOR EN10 EGO ENERGY REGULATOR HA112 SPOKED HANDWHEEL IS583 OE8802 BRATT PAN USER INS KN511 OPUS 800 KNOB BRATT PAN NE46 GREEN NEON NE47 AMBER NEON SO27 WATER VALVE NO SP92 LID SPRING SW80 GREEN BUTTON SOLID SW82 SWITCH ELEMENT N O TH63 SAFETY CUT OUT STAT 365 C TS03 TRAPEZOIDAL SCREW X54900 P ONLY MICRO SWITCH X59200 3P 40A TERMINAL BLOCK Y19200 SINGLE O...

Page 12: ...IS 583 ECN 3851 Page 12 of 14 900 800 770 800 1600 900 ...

Page 13: ...iently as possible please tell us Brief details of the problem Product code All available on serial plate Type number Serial number Lincat reserve the right to carry out any work under warranty given reasonable access to the appliance during normal working hours Monday to Friday 08 30 to 17 00 GUARANTEE This unit carries a comprehensive UK mainland 2 year warranty The guarantee is in addition to a...

Page 14: ...ised technician to carry out the warranty work Service calls to equipment under warranty will be carried out in accordance with the conditions of sale Unless otherwise specified a maximum of 15 minutes of administrative time not spent directly carrying out servicing work is provided for within the warranty Any requirement for staff attending the call to spend greater time than 15 minutes due to ad...

Reviews: