![Lincat OD7006 User, Installation, Servicing And Conversion Instructions Download Page 9](http://html.mh-extra.com/html/lincat/od7006/od7006_user-installation-servicing-and-conversion-instructions_1917327009.webp)
IS433 ECN3503
9
B
A
C
D
FF
HH
GG
KK
•
Remove the three pan supports AA, together with the control knobs CC.
•
Remove the fascia panel BB fixing screws EE from the underside of the panel.
Hob Valve Bypass Injectors
•
Remove the bypass injectors C from each of
the hob burner control valves B.
•
Replace the bypass injectors applicable to the
required gas type. Screw fully home but do
not over tighten.
Hob Burner Injectors
•
Remove pan supports.
•
Lift off the burner cap FF together with the burner base HH.
•
Remove injector GG and fit replacement applicable to the required gas type.
•
Replace burner base and cap.
•
Repeat the procedure for remaining hob burners.
Hob Burner Components
Part
Description
FF
Burner Cap
GG
Injector
HH
Burner Base
KK
Injector Holder
Completion of Conversion
•
Remove the redundant data plate and gas type identification label and attach new
replacements corresponding to new gas type.
Hob Tap Components
Part
Description
A
Manifold
B
Gas tap
C
Bypass injector
D
Clamp screw