Fit the new burner body and re-assemble parts.
Oven Fans
•
Ensure that the gas supply to this unit is turned off and the electrical supply is disconnected.
•
Remove the oven shelves.
•
Loosen the fan guard screws and lift off the keyhole slots.
•
Remove the hex head nut from the centre of the fan, this is a left-hand thread, and remove the
fan blade.
•
Working from the back of the unit, remove the rear cover panel.
•
Remove the electrical connections from the relevant motor.
•
Remove the three securing screws and extract the motor unit.
•
Refitting is the reversal of removal.
•
Check the unit for electrical safety.
Contactor
•
Ensure that the gas supply to this unit is turned off and the electrical supply is disconnected.
•
Working from the back of the unit, remove the rear cover.
•
Remove the electrical connections from the contactor.
•
Release the clip from the base of the contactor.
•
Refitting is the reversal of removal.
•
Check the unit for electrical safety.
Over Temperature Cut-Out Thermostat
•
Ensure that the gas supply to this unit is turned off and the electrical supply is disconnected.
•
Remove the thermostat bulb from the top of the oven.
•
Working from the back of the unit, remove the rear cover panel.
•
Remove the electrical connections from the thermostat housing.
•
Remove the front control panel.
•
Pull the thermostat bulb through the oven back.
•
Remove the two securing screws and remove the thermostat unit.
•
Refitting is the reversal of removal.
•
Check the unit for electrical safety.
Control Thermostat
•
Ensure that the gas supply to this unit is turned off and the electrical supply is disconnected.
•
Remove the thermostat bulb from the top of the oven.
•
Remove the control knobs from the front of the unit.
•
Remove the two screws holding the control thermostat to the control panel.
•
Remove the control panel as detailed previously.
•
Remove the electrical connections from the thermostat housing.
•
Remove the thermostat and capillary from the unit.
•
Refitting is the reversal of removal.
•