IT
IT
IT
IT----GB
GB
GB
GB----FR
FR
FR
FR mod. 698 TPC– 698 TP-SAC
67/116
M-2-4-04
START 2 WEEK-END
Insert 2 starting hour
14:00
M-2-4-05
STOP 2 WEEK-END
Insert 2 extinction hour
off
The program hours will be repeated every day of the week in the same way. For a correct
execution of the programs, set very carefully the data of Menu 01.
Selecting oFF instead of the starting or extinction hour, the stove exclude the automatic starting or
extinction
Menu 03 SELECT LANGUAGE - (setting up the language of the radiocontrol).
Radiocontrol Display
Description
Example
SELECT
LANGUAGE
Set up the language of the radiocontrol
ITALIAN
Available languages : ITALIAN, ENGLISH, DEUTSCH, FRANCAIS
Menu 04 SELECT FEELER (selecting room feeler).
Radiocontrol Display
Description
Example
Select feeler
Select which room temperature feeler you want to utilize
REMCONTR
Available selections : REMOTECONTROL, INTERNAL
REMOTECONTROL, The temperature will be taken from the radiocontrol.
INTERNAL, The temperature will be taken from the feeler put on the back of the appliance.
Menu 05 STATUS STAND-BY - (Set up way of appliance extinction according to the room
and boiler temperatures).
Radiocontrol Display
Description
Example
STATUS STAND-BY
Activate(on) / Disactivate(off) the stop modality if the set room
or boiler temperatures have been exceeded .
oFF
Available selections : on, oFF
ON, If the appliance is exceeding 2°C the set value of room or boiler temperature, it starts the
extinction cycle.
OFF, If the appliance is exceeding the set value of room or boiler temperature, it will continue to work
at min. power, without extinctinguishing.
Menu 06 STATUS BUZZER - (Setting up of buzzer sound).
Radiocontrol Display
Description
Example
STATUS BUZZER
Select the buzzer modality you wish
ONLY ALARM
Available selections: OFF, ONLY ALARMS, ALWAYS ON
OFF – Always off ONLY ALARMS – Sounds only if an alarm has occurred.
ON ALWAYS, sound in case of alarm and at any tuch of the buttons of the radiocontrol.
Menu 07 LOAD INITIAL - (Continuos fuel load setting).
Radiocontrol Display
Description
Example
LOAD INITIAL
Activates the continuos load of fuel
this operation can only be effected when the appliance on the display is evidencing “OFF”. This menu is
utilized to fill the screw feeder when the appliance is new or in case of emptying of the pellet container.
Menu 08 STATUS STOVE - (Displays the status of the appliance).
Radiocontrol Display
Description
Example
STATUS STOVE
Shows informations about the working of the appliance
Displayed values:
Fume temperature, fume expeller motor rev/min, appliance status, room temperature, boiler pressure,
time of fuel loading, and a screening of informations for TECHNICIANS.
Summary of Contents for Annarita 698 TP-SAC
Page 35: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 35 116...
Page 36: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 36 116...
Page 37: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 37 116...
Page 38: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 38 116...
Page 73: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 73 116...
Page 74: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 74 116...
Page 75: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 75 116...
Page 76: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 76 116...
Page 110: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 110 116...
Page 111: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 111 116...
Page 112: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 112 116...
Page 113: ...IT IT IT IT GB GB GB GB FR FR FR FR mod 698 TPC 698 TP SAC 113 116...