SECURITY DISTANCES
•
From NOT combustible object :
−
A > 600 mm
B > 100 mm
C > 100 mm
•
From combustible object and from principal wall in rein forced concrete :
−
A > 1200 mm
B > 200 mm
C > 200 mm
•
The minimal distance between the appliance and every flammable object around it is 1.5
meter.
1.4
Connection
•
Before connection check technical data reported in the technical plate ( Chap. 4) and
control that it correspond to the ones required in the order.
•
All heating biomass equipment especially wood appliance has to evacuate the
combustion products in a flue built in conformity with normative in force.
•
The following instructions describes „ informations for a good installation „ and it refers
to a normative in force but it are not to be consider exhaustive for installations laws.
COLLAR EXHAUST FUMES ASSEMBLY
•
Take off the collar from the fire door.
•
Place the collar on the top of the
appliance ( see the picture ) assemble
it with the screws.
Collar Exhaust
Fumes
Valid for all Model
To measure from apparatus external surface for every models