mod. 135GN-145GN GB 

 

5/20

 

Fig. 3 

Fig. 1 

Fig. 2 

1.4

 

Connection 

 

 

 

Before connection check technical data reported in the technical plate ( Chap. 4 ) and 
control that it correspond to the ones required in the order.  

 

All heating biomass equipment especially wood appliance has to evacuate the combustion 
products in a flue built in conformity with normative in force.  

 

The following instructions describes „  informations for a good installation „  and it refers 
to a normative in force but it are not to be consider exhaustive for installations laws. 

 

 
COLLAR EXHAUST FUMES ASSEMB LY  Fig.1 

 
Place the collar over the plate into special place.

 

 
 
 
 
 
 
 
 
 
HANDRAIL ASSEMB LING   Fig.2 
  

ƒ

 

To insert the caps “ D” on terminals 
support “ C”.  

ƒ

 

To insert the support “ C” in tube “ A” 
than fix it to the plate frame  with 
screws “ F” interposing  the  connection 
ring “ B”. 

 
 
 
 
 
 
 
 
 

TOP ASSEMBLING

  

Fig.3

 

 

 

To take the top out of wood drawer 

 

 

To put the top over wood cooker plate, insert 

the top pin into the right holes on plate fra me 
than screw it and tighten. 

 
 
 
 
 
 

Exhaust fumes collar  

Summary of Contents for 135GN

Page 1: ...Residential space heating appliances fired by Wood 1 20 Mod 135GN Mod 145GN USING INSTRUCTIONS AND MAINTENANCE Equipments built in conformity with European Norms for marking Cod 90003018 Rev 2...

Page 2: ...red IMPROPER USE of the equipment andtherefore UNCORRECTLY UTILIZATION with possibly ofdecay oftheguarantee INDEX Chap Description Pag 1 Installation 3 1 1 Normative and prescriptions 3 1 2 Preliminar...

Page 3: ...t fumes connections electricity water ventilation suction The manufacturer disclaims all responsibility caused by no correct installation using tampering maintenanceor no respectof normative inforce 1...

Page 4: ...m flammable object A 400 mm B 175 mm C 200 mm From flammable object and fromprincipal wall in rein forced concrete A 800 mm B 350 mm C 400 mm The minimal distance between the appliance and every flamm...

Page 5: ...ions for a good installation and it refers to a normative in force but it are not to be consider exhaustive for installations laws COLLAR EXHAUST FUMES ASSEMBLY Fig 1 Place the collar overthe plateint...

Page 6: ...fire of chimney or flue employ the right system to soffocate the flames and call for firefighter EQUIPMENT CONNECTION TO CHIMNEY FLUE AND EXHAUST COMBUSTION PRODUCTS It s advisable to read follow and...

Page 7: ...ination Roof C A H Re Flux Area Highness Z m 15 1 85 1 00 0 50 30 1 50 1 30 0 80 45 1 30 2 00 1 50 60 1 20 2 50 2 10 Re flux area Chimney pot wind damping Chimney Pot Wind Damping Revolving chimney po...

Page 8: ...ith grate or lath attention to not reduce the min section required on point a and placed so that to avoid obstruction The air inflow can be also supplied from the adjacent room but the air intake shou...

Page 9: ...ating volume favourable insulation m3 165 200 Heating volume unfavourable insulation m3 85 105 Flue gas temperature Medium Max C 290 310 265 285 Flue gas mass flow g sec 9 8 10 9 Chimney draft in Test...

Page 10: ...eillance The operation ofthe machine must always happen under surveillance Every maintenance operation every repairs or substitution should be done from qualify staffor assistance centre Useonly origi...

Page 11: ...r fumes outlet fromthe fire door To open the fire door employ the fixture enclosed STARTING AND FUNCTIONNING N B For starting never use alcohol fuel or others liquid combustibles In case ofstarting du...

Page 12: ...appliance is completely cold Be careful to the presence ofambers or warmpieces Do not forget to insert the ash drawerin its place The functioning ofthe appliance without the ash drawer has to be consi...

Page 13: ...igh heating performance Be careful to avoid the overheating of radiant plate because it damage seriously the equipment with any advantage in cooking performance COOKING OVEN The equipment is supplied...

Page 14: ...ioning phase the fire intensity regulation can be regulated with the prime air flask and the fumes valve The following indicatives positions are referring to an equipment in continuous running Models...

Page 15: ...ing EVERY DAY it s necessary to clean the foyer grate empty it from every residuals clean all the holes on the bottomand replaceit into its place External Cleaning This operation must be done when the...

Page 16: ...age ofthe parts NB In phaseofre assemble please care attention to the guideline ofthe folds ofthe oven plane during theinsertion Fig 8 It is lively advised to execute a checking and eventually the Cle...

Page 17: ...cation and eventually replacement ofgaskets Chimney verification We recommend to stipulate a contract with an after sales service We recommend to execute a regular maintenance of the appliance of the...

Page 18: ...een wood Appliance dirty inside Light on the appliancewith dried wood Call the assistance service Fumes escape from the equipment The fire ash door is open while the fire is burning Draft insufficient...

Page 19: ...__________________________________________________________________________ ___________________________________________________________________________ _________________________________________________...

Page 20: ...145GN GB 20 20 4 Technical data plate You find here enclosed a copy of technical data plate Lincar S p A Via E Fermi 5 42046 Reggiolo RE Italy Tel 39 0522 972260 Fax 390522973625 www lincar it info l...

Reviews: