Example of closed loop:

3

rd

. party site

In this state no notification

Example of Open Loop:

3

rd

. party site

In this state no notification

Features: 

• Add-on value for hospital & care bed
• Compact and functional design which allows easy mounting
• 2 connections, Port1 OpenBus™ connection / Port 5 Gateway
• Colour: Light grey RAL 7035
• Protection class IPX6
• Connection to OpenBus™ control box via modular plug cable, 6 wires
• Modular plug to Open end, see precautions.

Options (special article):

• Customised configuration (Configuration number ≥ 100)
• It is possible to define the OpenBus™ signals to be used for activating the relays and / or
  change the notification indicator, so that it fits to the customer’s system. 
  Please contact your Sales Engineer at LINAK A/S for further information. 

Usage: 

• Compatible with all LINAK OpenBus™ Control Boxes, light & full.
• Contact rating :

Max continuous current: 

= 1A

Max switching voltage:  

= 48 V (DC) 

Max switching capacity:  

= 24 VA

Contact resistance:  

< 100 mΩ

• Current consumption:

V bus 8V :  

<   9 mA

V permanent 40V :  

< 14 mA

•  Approvals: The MJB has been approved according to IEC60601-1:2005 3

rd

 edition, ANSI / AAMI

  ES60601-1:2005, 3

rd

 edition, and CAN / CSA-22.2 No 60601-1:2008

Summary of Contents for MJB

Page 1: ...Page 1 of 24 LINAK COM MEDLINE CARELINE MJB Gateway User manual...

Page 2: ...ion 6 Information on the MJB 6 Repairs 7 Misc on the MJB system 8 Warranty and service life 8 Maintenance 8 MJB GATEWAY variant 9 Standard functionality 9 Relay 1 and 2 9 Features 11 Options speciale...

Page 3: ...eave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK sub...

Page 4: ...nual If there is visible damage to the product it must not be installed The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervise...

Page 5: ...d in it Warning Always use locking mechanism and O ring Warning Sockets not used must be fitted with blind plugs to ensure IP degree The LINAK products cannot tolerate the influence of strong solvents...

Page 6: ...ntrol box is connected to the mains During operation Ensure that the cables are not damaged Unplug the mains cable on mobile equipment before it is moved Information on the MJB The MJB Modular Junctio...

Page 7: ...sassembled as much as possible at the disposal and that you try to recycle it As an example of main groups within sorting of waste we can mention the following Metal plastic cable scrap combustible ma...

Page 8: ...s warranty is only valid if the system is unopened and has been used correctly All LINAK products are designed to have an optimum service life as a matter of course but the expected service life in a...

Page 9: ...on the OpenBus Relay 1 can be activated via the patient control Key 1 Key 4 or the attendant control Key 2 Key 3 When a key is activated the relay will switch state from NO to NC for 2 seconds After 2...

Page 10: ...ake up Bed notification NC No notification NO Relay 2 CB power mode Notification level Relay state Mains unplugged or CB is in power down No notification NC On mains or battery at wake up Bed notifica...

Page 11: ...e Customised configuration Configuration number 100 It is possible to define the OpenBus signals to be used for activating the relays and or change the notification indicator so that it fits to the cu...

Page 12: ...s not able to identify the different products attached Before the final functional test in the production it is important that the system is re powered This is to ensure that all items have been detec...

Page 13: ...Gateway cable 3000 mm modular plug open end 0964140 1375 Gateway cable 1375 mm modular plug open end Please note the slit is placed on the opposite side of the modular plug This is to ensure that the...

Page 14: ...ond characteristic numeral is specified ingress of solid foreign objects first characteristic numeral is not specified and therefore replaced by the letter X in the code The materials are resistant to...

Page 15: ...d upwards from underneath the bed because it may enter the cable outlet Environmental conditions Environmental conditions Operating Temperature Relative humidity Atmospheric pressure 5 C to 40 C 20 to...

Page 16: ...cted to all ports in the MJB both ports with narrow and wide alignment grooves Modular plug with narrow alignment groove To be used with 3rd party products Can only be connected to ports in the MJB wi...

Page 17: ...ng Mark for Canada UL Listing Mark for Canada and the United States UL Listing Mark AS 3108 Australian approval mark Various T V Rheinland LGA tested Recognised Component Mark Canadian Recognised Comp...

Page 18: ...Conforms to ANSI AAMI Std ES60601 1 Cert to CSA Std C22 2 No 60601 1 C N 4008004 Conforms to ANSI AAMI Std ES60601 1 Cert to CSA Std C22 2 No 60601 1 C N 4008005 Conforms to ANSI AAMI Std ES60601 1 C...

Page 19: ...Page 19 of 24 MJB MJB Modular Junction Box DRAWING APPENDIX...

Page 20: ...operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature f...

Page 21: ...Page 21 of 24...

Page 22: ...Page 22 of 24...

Page 23: ...Page 23 of 24...

Page 24: ...India Liaison Office Tel 91 120 4531797 Fax 91 120 4786428 E mail info linak in www linak in Italy LINAK ITALIA S r l Tel 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it Japa...

Reviews: