MJB - GATEWAY variant, 504-010 & 504-020 :

The MJB is a simple gateway interface, which can connect switch input notifications from the 
infrastructure of the hospital or nursing home, such as service/nurse call systems. 
Please note that notifications are only to be used as service information and not for emergency issues.

Standard functionality:

The MJB - Gateway consist of two relays, which are connected through Port 5 on the MJB. This 
can be made with the special cable 0964140 (Modular plug - Open end) There are as standard 2 
configurations, 504-01 and 504-02, see description on the next pages.

Relay 1: NC (normally closed) = Pin 2 + Pin 1 / NO (normally open) = Pin 2 + Pin 3
Relay 2: NC (normally closed) = Pin 5 + Pin 4 / NO (normally open) = Pin 5 + Pin 6

Relay 1

 is NO when connected to the mains and NC when no mains, this means the relay is 

“active”, when connected to the mains (closed loop). The Closed Loop principal is to ensure that a 
notification is sent if power is missing on the bed. When the mains is disconnected (power is missing), 
the relay will go from NO to NC, which will automatically result in a notification (status indicator) on 
the OpenBus™.
Relay 1 can be activated via the patient control (Key 1 / Key 4) or the attendant control (Key 2 / Key 
3). When a key is activated, the relay will switch state from NO to NC for 2 seconds. After 2 seconds 
the relay will automatically change state from NC to NO.
The status of the relay is indicated on the OpenBus™ and can be used for switching on an LED.

Relay 2

 is as default NC, with or without mains, (Open Loop)

Relay 2 can be activated via the patient control (Key 1) or the attendant control (Key 2 / Key 3).
When the relay is activated, it will switch from NC to NO for 2 seconds. After 2 seconds the relay will 
automatically change state from NO to NC.
The status of the relay is indicated on the OpenBus™ and can be used for switching on an LED.
By using the variant 504-020 relay 2 will be controlled by the MJB variant 505/506 with switch input.
Notification 1 = Switch input S2 / notification 2 = Switch input S1
When using this combination, is it important to have the MJB 505/506 connected to the system all the 
time. If it is not connected, the Gateway MJB will see it as a notification and the relay will be activated. 
The Gateway MJB is 

“scanning”

 the OpenBus™ system every minute for a notification.

Port 5

Port 1

OpenBus connetion

Port 5: Relay connetions

Relay 1:

- Pin 1

- Pin 2

- Pin 3

Relay 2:

- Pin 4

- Pin 5

- Pin 6

NC

NO

NC

NO

Summary of Contents for MJB

Page 1: ...Page 1 of 24 LINAK COM MEDLINE CARELINE MJB Gateway User manual...

Page 2: ...ion 6 Information on the MJB 6 Repairs 7 Misc on the MJB system 8 Warranty and service life 8 Maintenance 8 MJB GATEWAY variant 9 Standard functionality 9 Relay 1 and 2 9 Features 11 Options speciale...

Page 3: ...eave the factory they undergo full function and quality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local dealer LINAK sub...

Page 4: ...nual If there is visible damage to the product it must not be installed The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervise...

Page 5: ...d in it Warning Always use locking mechanism and O ring Warning Sockets not used must be fitted with blind plugs to ensure IP degree The LINAK products cannot tolerate the influence of strong solvents...

Page 6: ...ntrol box is connected to the mains During operation Ensure that the cables are not damaged Unplug the mains cable on mobile equipment before it is moved Information on the MJB The MJB Modular Junctio...

Page 7: ...sassembled as much as possible at the disposal and that you try to recycle it As an example of main groups within sorting of waste we can mention the following Metal plastic cable scrap combustible ma...

Page 8: ...s warranty is only valid if the system is unopened and has been used correctly All LINAK products are designed to have an optimum service life as a matter of course but the expected service life in a...

Page 9: ...on the OpenBus Relay 1 can be activated via the patient control Key 1 Key 4 or the attendant control Key 2 Key 3 When a key is activated the relay will switch state from NO to NC for 2 seconds After 2...

Page 10: ...ake up Bed notification NC No notification NO Relay 2 CB power mode Notification level Relay state Mains unplugged or CB is in power down No notification NC On mains or battery at wake up Bed notifica...

Page 11: ...e Customised configuration Configuration number 100 It is possible to define the OpenBus signals to be used for activating the relays and or change the notification indicator so that it fits to the cu...

Page 12: ...s not able to identify the different products attached Before the final functional test in the production it is important that the system is re powered This is to ensure that all items have been detec...

Page 13: ...Gateway cable 3000 mm modular plug open end 0964140 1375 Gateway cable 1375 mm modular plug open end Please note the slit is placed on the opposite side of the modular plug This is to ensure that the...

Page 14: ...ond characteristic numeral is specified ingress of solid foreign objects first characteristic numeral is not specified and therefore replaced by the letter X in the code The materials are resistant to...

Page 15: ...d upwards from underneath the bed because it may enter the cable outlet Environmental conditions Environmental conditions Operating Temperature Relative humidity Atmospheric pressure 5 C to 40 C 20 to...

Page 16: ...cted to all ports in the MJB both ports with narrow and wide alignment grooves Modular plug with narrow alignment groove To be used with 3rd party products Can only be connected to ports in the MJB wi...

Page 17: ...ng Mark for Canada UL Listing Mark for Canada and the United States UL Listing Mark AS 3108 Australian approval mark Various T V Rheinland LGA tested Recognised Component Mark Canadian Recognised Comp...

Page 18: ...Conforms to ANSI AAMI Std ES60601 1 Cert to CSA Std C22 2 No 60601 1 C N 4008004 Conforms to ANSI AAMI Std ES60601 1 Cert to CSA Std C22 2 No 60601 1 C N 4008005 Conforms to ANSI AAMI Std ES60601 1 C...

Page 19: ...Page 19 of 24 MJB MJB Modular Junction Box DRAWING APPENDIX...

Page 20: ...operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying conditions application vibration load humidity temperature f...

Page 21: ...Page 21 of 24...

Page 22: ...Page 22 of 24...

Page 23: ...Page 23 of 24...

Page 24: ...India Liaison Office Tel 91 120 4531797 Fax 91 120 4786428 E mail info linak in www linak in Italy LINAK ITALIA S r l Tel 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it Japa...

Reviews: