background image

Page 17 of 44

Position of the internal eye

Connector for extension eye 

Remote control HB10RF / HB20IR

Operation of the system:

The HB21 IR transmitter is a simple up/down control with a button for the up 
activation and a button for the down activation of 1 reference on the CBD.

The HB22 is a two-channel controller, for controlling two references on the CBD.

For activation of the control box point with the HB20 at the DP1V or the extension eye: Press the button up or down.

The operation range for the HB20 is approx. 6 m.

Drawings:

DP1V

IR extension eye article number 0964571 

The IR extension eye is for mounting in a 12 mm hole. The eye has a 2000 mm cable with a mini Jack plug, which is to be 
plugged into the DP1V.

Summary of Contents for DESKLINE DP

Page 1: ...Page 1 of 44 To learn more about LINAK please visit w w w l i n a k c o m U S E R M A N U A L Controls Handsets...

Page 2: ...Page 2 of 44...

Page 3: ...vating the learning mode 18 Operation of the DPF 19 K version 19 2K and 3K version 19 M version 19 Operation of the DPF1C one reference 20 Operation of the DPF1D 21 Operation of the DPF4T multiple ref...

Page 4: ...ucts leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your systems you are always welcome to contact your local dealer LINAK subsidiari...

Page 5: ...th the NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and a...

Page 6: ...knowledge of the product products must not use the product products Besides persons with reduced physical sensory or mental abilities must not use the product products unless they are under surveilla...

Page 7: ...workshops or repairers as special tools must be used and special gaskets must be fitted Lifting units under warranty must also be returned to authorised LINAK workshops Warning If any of the DESKLINE...

Page 8: ...heck for correct functioning as well as fixing points The cleaners and disinfectants must not be highly alkaline or acidic pH value 6 8 ETL marking Due to space limitations the complete ETL marking de...

Page 9: ...Std ES60601 1 Cert to CSA Std C22 2 No 60601 1 ETL Recognized Component mark for Canada and United States C N 4009507 Conforms to UL962 Cert to CSA Std C22 2 No 68 09 ETL Recognized Component mark fo...

Page 10: ...mory DPA DPB DP1K DP1V DPF1K DPH and DPF1D For drive of more references DPF4T DPF2K and DPF3K DPF2K Desk Panel DPF3K Desk Panel DPF4T Desk Panel For single parallel drive with memory DP1N DP1U DP1CS D...

Page 11: ...DPA DPB in connection with DESKLINE systems not CBD2N The Desk Panel is used to operate the DESKLINE system The two arrow buttons are used for parallel drive Parallel drive The arrow buttons start pa...

Page 12: ...n the button S U 1 2 3 DP1U Desk Panel 2 1 3 S DPA Desk Panel DP1K Desk Panel DPB Desk Panel DP1V Desk Panel DP 025 2 1 U S DP1N Desk Panel DPH Desk Panel Store memory Push Within two sec push either...

Page 13: ...e upwards when you press the Down button While running to a memory position the display will show GO1 GO2 or GO3 and when it stops in the stored position the height of the desk will be shown Releasing...

Page 14: ...be displayed when a button is pressed The display blinks while showing the error E16 overrules any other error as the detection is registered only in the display and no message is sent to the control...

Page 15: ...sition Memory The four small buttons are used for memory drive storing memory Store memory Press S button the display will flash S for 2 seconds Within these two seconds press one of the small buttons...

Page 16: ...een reached The system will return to normal operation and give a short blink after 5 seconds of inactivity on the keys The feature can be disabled via configuration in which case pressing the and key...

Page 17: ...eference on the CBD The HB22 is a two channel controller for controlling two references on the CBD For activation of the control box point with the HB20 at the DP1V or the extension eye Press the butt...

Page 18: ...l Every RF handset has its own 32 bit unique address and the RF protocol contains a check sum which ensures that only the handset that has been activated during the learning process can activate the s...

Page 19: ...ystem will drive until the button is released again or the system reaches end position 2K version Just activate either the up or down button and the system will drive until the button is released agai...

Page 20: ...flash for 2 seconds Within these two seconds press one of the small buttons with dots and the position will be stored at this button The panel will acknowledge by showing 1 2 or 3 in the display depe...

Page 21: ...when adjusting and error codes when needed Up and down V You just either have to activate the up or down button for parallel drive and the system will drive until releasing the button again or when t...

Page 22: ...emory The four small buttons are used for toggle function memory drive and storing memory Store memory Press S button the display will flash for 2 seconds Within these two seconds press one of the sma...

Page 23: ...ith impulse Memory positions 1A The memory position will be for all references When using memory one or two reference one will first drive to its memory position followed by reference two and so on Ot...

Page 24: ...eys are pressed Mounting of all DPF versions The DPF must be mounted via a mounting bracket The mounting bracket comes in 4 different versions depending on how the panel should be mounted Below are so...

Page 25: ...Page 25 of 44 Drawings of the mounting brackets Article number 914759 Article number 914757 Article number 914760 Article number 914785...

Page 26: ...While the S is displayed touch the memory button 1 2 or 3 The display will acknowledge by showing S1 S2 or S3 for 1 sec To abort a store sequence press the or button while the S is flashing or wait th...

Page 27: ...ll blink while showing the error E16 overrules any other error since the detection is registered only in the display and no message is sent to the control box For detailed error description and codes...

Page 28: ...ess which can destroy the product when transported 2 For countersink versions the technician must ensure that the acrylic plate is not put under pressure which will push the acrylic plate out of place...

Page 29: ...Change batteries at weak contrast in the display or when the display shows strange symbols misinformation This does not influence the function of the WDPL it is exclusively a sign that the batteries a...

Page 30: ...o select Desk ll or lll 4 Press and hold and then press or to adjust the height in the display Example The display will switch from e g 68 to 69 70 71 etc when is pressed and held and then is pressed...

Page 31: ...nfirm time mode using a ball pen 2 Press or to adjust hh 3 Press the clock button again to confirm hh 4 Press or to adjust mm 5 Press the clock button again to confirm mm Display view Action Flashing...

Page 32: ...desk go through points 3 to 6 again If the buttons are not activated for 15 sec the clock function will appear in the display If only one desk is connected go to point 4 1 Press 2 Press or until the...

Page 33: ...ll desks have reached their memory position The display will show the height of the moving desk for about 15 sec Display view Action Position l is flashing digits counting from 117 to 88 When the desk...

Page 34: ...ontents if any Main groups of disposal Product main groups Metal Scrap Cable scrap Electronics scrap Plastic recycling or combustion Comments DPXX X X X WDPL X X X Disposal of batteries Details regard...

Page 35: ...ectly on the DPA Label for DPB DPBK06 P O 299218 DPBK06 P O 299218 The label is printed directly on the DPB Label for WDPL Label for DPF Label for DPF1C Label for DPT Label for DPH Label for DP1CS Lab...

Page 36: ...Page 36 of 44 DESKLINE DRAWING APPENDIX DPB with drawer DPA 55 5 49 6 33 5 25 5 8 28 4 4 24 53 4 13 157 5 135 112 5...

Page 37: ...Page 37 of 44 DP1C Desk Panel DPF1K Desk Panel DP1CS Desk Panel Drawing No DP1C 161 84 42 8 5 4 5 25 5 Drawing No DP1C...

Page 38: ...Page 38 of 44 DPF3K Desk Panel Drawing No DPF3_K 130 25 5 18 5 15 Drawing No DPF3_K DPF2K Desk Panel 93 5 25 5 18 5 15...

Page 39: ...Page 39 of 44 DPF1C Desk Panel with display 130 25 19 15 DPF1D Desk Panel DPF1M Desk Panel 93 5 18 5 15 25 5...

Page 40: ...Page 40 of 44 DPH Desk Panel DPT Desk Panel DPF4T Desk Panel...

Page 41: ...Page 41 of 44 WDP fitting for desk 110 179 9 49 5 5 9 6 25 7 WDP...

Page 42: ...Page 42 of 44...

Page 43: ...der which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying condition...

Page 44: ...UK Mobile 35 387 634 6554 Republic Of Ireland Mobile E mail sales linak co uk www linak co uk ITALY LINAK Italia S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it J...