Page 14 of 44
Error no.
Description
E01
The desk has an unknown position and needs to be initialised.
E02
Overload upwards has occurred.
E03
Overload downwards has occurred.
E16
Illegal keys pressed.
will show the current setting. Keep the “3” button pressed during the whole sequence while adjusting up or down. Keep a
button pressed for more than 800 msec, then the button will auto repeat every 100 msec. Releasing all buttons stores the new
setting.
Errors
Below please find the possible errors that can be displayed. The errors will only be displayed when a button is pressed. The
display blinks while showing the error. E16 overrules any other error as the detection is registered only in the display and no
message is sent to the control box.
Diagnostic errors
The CBD4 (version 1.86 or later) can send up to 6 different diagnostic error codes at the same time.
The diagnostic error codes will overrule error states (except E16). Diagnostic errors will only appear as long as the button is
pressed. The display will blink EXX and will toggle through the diagnostic errors and send them to the LINBUS in the CBD. For
detailed error description and codes, please see the appropriate CBD software description.
(Only working with DP1C from production date 1 february 2006 and onwards)