background image

Page 14 of 36

Description of the DESKLINE

®

 DL5/DL6 system

Each DESKLINE

®

 DL5/DL6 lifting units is equipped with a motor and parallel/memory drive is ensured by means of software in 

the CBD6S (SMPS) that also takes account of oblique load on the desk. Soft start and stop are also part of this software, which 
ensures a soft start and stop when adjusting the desk.

Application of the DESKLINE

®

 DL5/DL6 system:

Irrespective of the load the 

duty cycle 10% ≈ 2 minutes of continuous use at full load, followed by 18 minutes of 

pause 

stated in the data sheets, must 

NOT

 be exceeded as this will result in a superheating of the motor, the brake and the 

spindle nut. Exceeding the duty cycle will result in a considerable reduction of the life of the system.

The DESKLINE

®

 DL5/DL6 system range contains the following products:

•  1 control box CBD6S 200 W or CBD6S 300 W (SMPS - Switch Mode Power Supply)
•  1 single DL5 standard / DL5 PLUS

TM

 / DL6 standard / DL6 PLUS

TM

 / DL6 PLUS™ High-speed, or 2 in parallel 

•  1 exchangeable mains cable  
•  1 or 2 motor cables
•  DP1U/DPF1M/DPG1M/DPG1B (if memory function is required) 
  DP1C/DPT/DPF1C/DPG1C (if memory function and display is required) or
  DPA/DPB/DPH/DP1K/DP1V/DPF1K/DPG1K (if only up/down is required) or DPF1D (if display is required).

Summary of Contents for DESKLINE DL5

Page 1: ...Page 1 of 36 LINAK COM DESKLINE DL5 DL6 with CBD6S User manual...

Page 2: ...system 11 Warranty 11 Maintenance 11 Service of double insulated products 12 ETL markering 13 Description of the DESKLINE DL5 DL6 system 14 Installation 15 Mounting the motor housing 15 Mounting of th...

Page 3: ...ality testing Should you nevertheless experience problems with your LINAK product system you are always welcome to contact your local contact LINAK subsidiaries and some distributors situated all over...

Page 4: ...L5 standard DL5 PLUSTM DL6 standard DL6 PLUSTM DL6 PLUS High speed or 2 in parallel Control boxes CBD6S 200 W CBD6S 300 W Controls DPF1M DPG1M DPG1B if memory function is required DP1CS DPT DPF1C DPG1...

Page 5: ...NOTE symbol may result in serious damage to the system or one of its components It is important for everyone who is to connect install or use the systems to have the necessary information and access...

Page 6: ...ndividual parts must be connected before connecting the control box to the mains See the User Manual for LINAK actuators if necessary During operation If the control box makes unusual noise or smells...

Page 7: ...ce or knowledge of the product products must not use the product products Besides persons with reduced physical sensory or mental abilities must not use the product products unless they are under surv...

Page 8: ...pecial gaskets must be fitted Products under warranty must also be returned to authorised LINAK service centres Further information on DESKLINE warranty can be found on the LINAK website www linak com...

Page 9: ...a0b00470645 where a can be 0 or R b can be A B C or D DL2 DL2abCcdefffggg where a can be 3 6 or 7 b can be from 0 to 3 c can be A or B d can be 0 F or G e can be from 0 to 7 fff can be from 300 to 500...

Page 10: ...n be from 300 to 500 ggg can be from 445 to 655 BASELIFT BASE1000A0F100100 Desk Panel s DPA DPB DPH DPF1K DPF1M DPF2K DPF3K DPF1C DPF1D DPF1U DPF1W DPF4T DPG1K DPG1M DPG1B DPG1C DPT DP1V01 DP1CS DP1K...

Page 11: ...d plugs and check for correct functioning as well as fixing points Cleaning the desk panel Clean your desk panel with a soft damp cloth Universal cleaning detergents may be used For disinfection of th...

Page 12: ...usually achieved at least in part by having two layers of insulating material surrounding live parts or by using reinforced insulation There is no earthing grounding means provided on the product and...

Page 13: ...CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United States C N 4009507 Conforms to UL962 Cert to CSA Std C22 2 No 68 09 ETL Recognized Component mark for Canada and United Stat...

Page 14: ...e stated in the data sheets must NOT be exceeded as this will result in a superheating of the motor the brake and the spindle nut Exceeding the duty cycle will result in a considerable reduction of th...

Page 15: ...to get easy desk assembly LINAK recommends using the DL5 DL6 DESKLINE system in push applications with the motor housing mounted upwards The motor housing is supplied with six M6 threaded holes for mo...

Page 16: ...llowing specifications Quality Min grade 8 8 Length Min 10 mm plus foot thickness Max 16 mm plus foot thickness for M6 Max 14 mm plus foot thickness for M8 2 Fasten screws thoroughly torque max 10 Nm...

Page 17: ...bracket where the bracket has been pulled out when tightening the crossbar To eliminate this failure please follow the guidelines below when constructing a desk Requirement Min 1 mm space between end...

Page 18: ...ing the tabletop The sound from the lifting column spreads as vibrations to the tabletop which amplifies the sound This can however be reduced 1 Place vibration shock absorbing material between tablet...

Page 19: ...of 10 mm 8 to 10 mm can be used 5 Fasten the mounting screws max torque 1 Nm Notes If the control box is mounted in a top frame bar with the width of the motor housing it can be mounted with one screw...

Page 20: ...to the tabletop using a clip observing the 30 mm minimum bending radius R Connecting the system 1 Connect the first DL DB to socket 1 next to port A2 on the control box using the 6 pin plug on the mo...

Page 21: ...mm out again Do not release the down button until the movement has stopped completely If the button is released before the sequence is completed the initialisation is interrupted and must be started...

Page 22: ...otecting the desk from being damaged when driven into such objects This feature is called an anti collision system To a certain extent this feature also increases the personal safety but it does not c...

Page 23: ...with legislation describing personal safety PIEZO allows the DL6 columns to have the standard built in dimension and the standard stroke length There are no visible changes to the column The Desk Sen...

Page 24: ...ly and all lifting columns will start to run in the opposite direction approx 50 mm This return drive is done automatically and continues with or without any control key pressed for max 2 5 sec The an...

Page 25: ...ributor or subsidiary Accessories Please contact your nearest LINAK contract distributor or subsidiary Warning By unauthorised opening of the system there is a risk that it may malfunction at a later...

Page 26: ...almost all our cast plastic parts are supplied with an interior code for plastic type and fibre content if any Main groups of disposal Product main groups Metal scrap Cable scrap Electronics scrap Pla...

Page 27: ...Page 27 of 36 Label for DL5 Label for CBD6S 200 W SMPS Label for CBD6S 300 W SMPS up to 4 channels Labels Label for DL6 PLUSTM Label for DL6 Label for DL5 PLUSTM...

Page 28: ...nation code B Built in length mm S Stroke length mm O Outer profile length mm EU DL5xxxxxx645500 645 500 590 DL5 DL5 motor housing and profile dimensions mm DRAWING APPENDIX DL5 motor housing and prof...

Page 29: ...Page 29 of 36 Bracket options dimensions in mm Combination code Std bracket Bench left Bench right DL5xx1xxxxxxxxx X DL5xxLxxxxxxxxx X DL5xxRxxxxxxxxx X DL5 Bracket options...

Page 30: ...ode B Built in length mm S Stroke length mm O Outer profile length mm EU DL6xxxxxx650560 560 650 498 BIFMA DL6xxxxxx665518 518 665 456 DL6 DL6 motor housing and profile dimensions mm DL6 motor housing...

Page 31: ...mbination code Std bracket Bench left Bench right DL6xx1xxxxxxxxx X DL6xxLxxxxxxxxx X DL6xxRxxxxxxxxx X DL6 Bracket options 27 60 60 Created By Mads Boyschau Eskildsen 2019 12 04 Modified By Bjarne Sk...

Page 32: ...Page 32 of 36 Socket Socket combination Combination code Type DL5xxxxx0xxxxxx Standard DL6xxxxx0xxxxxx Standard DL6xxxxxExxxxxx Standard Standard Standard PLUSTM Profile designs...

Page 33: ...Page 33 of 36 Standard bracket...

Page 34: ...Page 34 of 36 CBD6S 200 W SMPS CBD6S 300 W SMPS up to 4 channels...

Page 35: ...under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and its performance under varying condit...

Page 36: ...011 4303 8989 8900 Fax 011 4032 0184 www novotecargentina com Colombia MEM Ltda Tel 57 1 334 7666 Fax 57 1 282 1684 www mem net co India Mechatronics Control Equipments India Pvt Ltd Tel 91 44 2855848...

Reviews: