Page 14 of 36
Description of the DESKLINE
®
DL5/DL6 system
Each DESKLINE
®
DL5/DL6 lifting units is equipped with a motor and parallel/memory drive is ensured by means of software in
the CBD6S (SMPS) that also takes account of oblique load on the desk. Soft start and stop are also part of this software, which
ensures a soft start and stop when adjusting the desk.
Application of the DESKLINE
®
DL5/DL6 system:
Irrespective of the load the
duty cycle 10% ≈ 2 minutes of continuous use at full load, followed by 18 minutes of
pause
stated in the data sheets, must
NOT
be exceeded as this will result in a superheating of the motor, the brake and the
spindle nut. Exceeding the duty cycle will result in a considerable reduction of the life of the system.
The DESKLINE
®
DL5/DL6 system range contains the following products:
• 1 control box CBD6S 200 W or CBD6S 300 W (SMPS - Switch Mode Power Supply)
• 1 single DL5 standard / DL5 PLUS
TM
/ DL6 standard / DL6 PLUS
TM
/ DL6 PLUS™ High-speed, or 2 in parallel
• 1 exchangeable mains cable
• 1 or 2 motor cables
• DP1U/DPF1M/DPG1M/DPG1B (if memory function is required)
DP1C/DPT/DPF1C/DPG1C (if memory function and display is required) or
DPA/DPB/DPH/DP1K/DP1V/DPF1K/DPG1K (if only up/down is required) or DPF1D (if display is required).