Pipe diameter must not be less than the appliance
spigot diameter.
-
If there is no other solution, the reduction can not be
more than one diameter lower than the flue spigot and
be situated as distant as possible from the flue
connection of the appliance.
-
The connection can be either vertical or horizontal. For
horizontal connections, avoid right angle bends.
-
The join between the connection pipe and the
stovepipe, and the flue, must be leak tight.
-
For the premises equipped with a mechanical
controlled ventilation, the airtightness has to prevent
the exhauster drawing out the smokes from the
exhaust gas pipe.
-
The connection pipe and any draught stabiliser must
have access for cleaning.
2.6. Mounting the tray
Figure 6
To avoid damage during transport, the tray has been
stored behind the main door.
-
Fix the tray on the appliance.
-
Centre on tab “A” and lower into place.
2.7. Pre-utilisation check
-
Check that the glass is not damaged.
-
Check that the smoke passages are not obstructed by
packaging or removable parts.
-
Check that the seals of the smoke-line are in good
condition.
-
Check that the doors close correctly.
-
Check that all removable parts are correctly installed.
(side walls, flue baffle, grates, etc.)
Note :
if it acts of a ceramics braid, it is consumable and
thus brought to be changed by the user
6
Technical manual “1054”
Limousin ~ Mod 134 10 12
Installation instructions
1
2
3
4
1
1
3
6
4
5
Figure 5 - Chimney
connections
A
Figure 6 - Mounting the tray
1
- Chimney
2
-
F u n n e l - s h a p e
fireproof material
3
- Non combustible
register plate
4
- Cleaning access
door
5
- Liner