background image

4. Spare parts

When ordering spare parts, specify

the stove type

and

serial number

, including the

colour index

(on the

guarantee or identification plate),

the name

of the part and

the part number

.

Example : Multifuel stove ”

Limousin

”, ref.

134 10 12

, color

Y

, Top plate

352124 EF

.

A

= 134 10 12 Y

B

= 134 10 12 E

Limousin ~ Mod 134 10 12

Spare parts

Technical manual “1054”

11

Code

Description . . . . . . . . . . . Type . . . . . . . . . . A . . . . B . . . . Qty

1

100939

Axle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 04

2

101048

Axle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 02

3

110404

Hinge pin . . . . . . . . . . . . . 6x30 . . . . . . . . . . A . . . . B . . . . 02

4

110405

Hinge pin . . . . . . . . . . . . . 6x35 . . . . . . . . . . A . . . . B . . . . 02

5

134107

Glove . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

6

134711

Pin . . . . . . . . . . . . . . . . 6x30 . . . . . . . . . . A . . . . B . . . . 02

7

134749

Pin . . . . . . . . . . . . . . . . 4x20 . . . . . . . . . . A . . . . B . . . . 02

8

142301

Adhesive rope . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . 1,32 m

9

162721

Descriptive plate . . . . . . . . . . 9 . . . . . . . . . . . A . . . . B . . . . 01

10

181607

Ceramic rope . . . . . . . . . . Ø 9,5 . . . . . . . . . . A . . . . B . . . 1,00 m

11

181614

Ceramic rope . . . . . . . . . . Ø 9,5 . . . . . . . . . . A . . . . B . . . 3,40 m

12

181615

Ceramic rope . . . . . . . . . . . Ø 12 . . . . . . . . . . A . . . . B . . . 1,77 m

13

188780

Ceramic glass . . . . . . . . 439x272x4 . . . . . . . . A . . . . B . . . . 01

14

205391

Back panel . . . . . . . . . . . . . 14 . . . . . . . . . . . A . . . . B . . . . 01

15

209915

Protector . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

16

222609

Suppl. flue baffle . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

17

237413 60

Reducing plate . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

18

259015

Fixing plate . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 04

19

270409

Air control flap . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

20

270410 60

Air control flap . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

21

300122 EF

Leg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 04

21

300122 RP

Leg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 04

22

300462 EF

Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 01

22

300462 RP

Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 01

23

300991 EF

Handle. . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 02

23

300991 RP

Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 02

24

303515 EF

Loading door . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 01

24

303515 RP

Loading door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 01

25

303718 EF

Blanking plate. . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 01

25

303718 RP

Blanking plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 01

26

303826 EF

Flue collar . . . . . . . . . . . Ø 153 int. . . . . . . . . . A . . . . . . . . . . 01

26

303826 RP

Flue collar . . . . . . . . . . . Ø 153 int. . . . . . . . . . . . . . . B . . . . 01

27

305015

Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

28

305150

Back wall . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

29

306278 EF

Back wall . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 01

29

306278 RP

Back wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 01

30

307422 EF

Fuel retainer . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 02

30

307422 RP

Fuel retainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 02

31

308712

Coal grate . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

32

309897 EF

Front plate . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 01

32

309897 RP

Front plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 01

33

310729 EF

R. side panel . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 01

33

310729 RP

R. side panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 01

34

310826 EF

L. side panel . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 01

34

310826 RP

L. side panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 01

35

314607

Inner door . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

36

315602

Air duct . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

37

323211

Flue baffle. . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . B . . . . 01

38

325304 EF

Reducing plate . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 03

38

325304 RP

Reducing plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 03

39

327901 EF

Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . 01

39

327901 RP

Tray. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B . . . . 01

Summary of Contents for 134 10 12

Page 1: ...of 6 359 540 Head Office Address 2 rue Saint Gilles 68230 TURCKHEIM RCS Colmar SIREN 444 881 953 Address Administration and manufacturing BP 73 59660 MERVILLE FRANCE Telephone 00 333 28 43 43 00 Fax 00 333 28 43 43 99 Subject to modifications LIMOUSIN Multifuel stove Model 134 10 12 Output 10 kW DIN EN 13240 2005 10 Technical manual to be saved by the user for future reference ...

Page 2: ... p 9 Recommendations p 9 Trouble Shooting p 10 Spare parts p 11 FRANCO BELGE congratulates you on your choice FRANCO BELGE guarantees the quality of its appliances and is committed to meet its customers needs FRANCO BELGE which can boast a 80 year experience in the industry of heating devices uses state of the art technologies to design and manufacture its whole range of products This document con...

Page 3: ...ture C 234 Fuel rate kg h 1 7 Efficiency 67 Co 13 O2 0 24 1 4 Description Stove in conformity with DIN EN 13240 2005 10 Intermittent burning heating appliance Detachable flue collar for rear or top chimney connection Detachable top for easy handling and cleaning rear flue outlet only Adjustable air control for controlling the burning rate Air control for lighting Large ash pan Side loading door 1 ...

Page 4: ... materials If the appliance has to be located in an opening this distance must be extended to a minimum clearance A of 375 mm from the pipe or the stove body to any combustible materials Hearth The appliance must stand on a fireproof hearth It is possible to provide a hearth made of non combusible board sheet material or tiles at least 12 mm thick Constructional hearths should be constructed of so...

Page 5: ...and washers supplied Replace the flue baffle Replace the top plate Remove the cut out in the rear heat shield and refit 2 4 2 Flue outlet on the top Figure 4 Remove the top plate 2 screws Remove the flue baffle Remove the blanking plate 3 and the clamp 5 and refit them at the rear ensuring there is a good seal Fix the flue collar 1 on the top with 3 bolts and washers supplied ensuring there is a g...

Page 6: ...r cleaning 2 6 Mounting the tray Figure 6 To avoid damage during transport the tray has been stored behind the main door Fix the tray on the appliance Centre on tab A and lower into place 2 7 Pre utilisation check Check that the glass is not damaged Check that the smoke passages are not obstructed by packaging or removable parts Check that the seals of the smoke line are in good condition Check th...

Page 7: ...himney catches fire you must cut off the flue draught close the doors and windows hatches and keys remove the embers from the stove stop up the connection hole with wet cloths and call the Fire Brigade DO NOT OPEN THE DOOR OF THE APPLIANCE OR AIR INLET UNDER ANY CIRCUMSTANCES Chimney condition should be checked at least once per year by a professional engineer Limousin Mod 134 10 12 Installation i...

Page 8: ...uel This appliance is not an incinerator Use hard wood logs which have been cut for at least two years and stored under a ventilated shelter Use hardwood that have a higher calorific value per cu metre Yoke elm oak ash maple birch elm beech etc Large logs must be split and cut to an useful length before being stored in a sheltered and ventilated place Recommended fuel The best fuels for use with t...

Page 9: ...urning smokeless fuel always empty the ash pan at least once a day or whenever it is full of ashes Never allow the ashpan to overfill allowing ash to be in contact with the underside of the grate If this condition is allowed the grate will wear out pre maturely 3 5 Maintenance of the Chimney Very important In order to avoid any incident chimney fire etc maintenance tasks must be carried out regula...

Page 10: ...uality wood Do not continuously burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression In houses equipped with mechanical ventilation partly open a window until the fire is well established Smokes while burning Draught is insufficient þ Consult a chimney specialist Check t...

Page 11: ...ffle A B 01 17 237413 60 Reducing plate A B 01 18 259015 Fixing plate A B 04 19 270409 Air control flap A B 01 20 270410 60 Air control flap A B 01 21 300122 EF Leg A 04 21 300122 RP Leg A B 04 22 300462 EF Base A 01 22 300462 RP Base B 01 23 300991 EF Handle A 02 23 300991 RP Handle B 02 24 303515 EF Loading door A 01 24 303515 RP Loading door B 01 25 303718 EF Blanking plate A 01 25 303718 RP Bl...

Page 12: ... 1 2 3 3 5 6 7 8 9 1 0 1 1 1 1 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 4 1 4 2 4 4 4 5 1 1 1 2 4 4 6 7 1 0 1 2 2 3 3 0 3 8 3 8 4 3 2 1 2 1 2 1 4 6 4 8 4 7 4 9 Figure 10 Stove exploded view ...

Page 13: ...r A 01 40 331108 RP Main door B 01 41 352124 EF Top plate A 01 41 352124 RP Top plate B 01 42 406816 Clamp A B 01 43 415504 60 Poker A B 01 44 624043 Ash pan A B 01 45 808001 ED Hand tool A B 01 46 262608 Heat shield A B 01 47 122820 Name plate A B 01 48 161061 Touch up paint B 01 A 134 10 12 Y B 134 10 12 E Note ...

Page 14: ... two years for all appliances with the exception of closed combustion fireplace and inserts for which our guarantee is 5 five years excluding the following 1 Indicator lights fuses electrical elements and fans 2 Parts subject to wear or in contact with high temperatures namely soles and burner grills bottom plates baffles ash pans paintwork and surface treatments for decorative parts Also excluded...

Reviews: