If the chimney draught is excessive or irregular, a
draught stabiliser (barometric damper) must be
installed to the connector pipe.
Chimney to be built / New flue
-
The chimney must comply with Current Building
Regulations. If in doubt, consult your Dealer or local
Building Inspector.
-
The appliance must not support the weight of the flue.
-
Consult a chimney specialist for advice on suitable
flue systems for solid fuel appliances.
-
It must be distant from any combustible material
(walls, cross members)
-
It must permit an easy sweeping.
2.4. Mounting the flue collar
The stove is supplied with a connection flue collar with
an inner diameter of 153 mm.
2.4.1. Flue outlet at rear
Figure 3
-
Remove the rear heat shield 5.
-
Remove the top plate (2 screws).
-
Remove the flue baffle.
-
Fit the sealing rope 2 in the groove at rear and fix the
flue collar 1 with 3 bolts and washers supplied.
-
Replace the flue baffle.
-
Replace the top plate.
-
Remove the cut-out in the rear heat shield and refit.
2.4.2. Flue outlet on the top
Figure 4
-
Remove the top plate (2 screws).
-
Remove the flue baffle.
-
Remove the blanking plate 3 and the clamp 5 and refit
them at the rear, ensuring there is a good seal.
-
Fix the flue collar 1 on the top with 3 bolts and washers
supplied, ensuring there is a good seal.
-
Replace the flue baffle.
-
Replace the top plate.
In this case, the cut-out of the heat shield must not be
remove.
2.5. Connection to flue
-
The stove must be installed as close as possible to the
chimney.
-
The stove should be connected to the flue by a smoke
pipe, approved for installation with combustion
products (e.g. 316 grade 1 mm thick stainless steel or
vitreous enamelled steel).
Limousin ~ Mod 134 10 12
Installation instructions
Technical manual “1054”
5
7
4
1
2
3
6
Figure 3 - Rear flue outlet
1
2
3
4
5
2
7
Figure 4 - Smoke exit from top
1
- Flue collar
2
- Ceramic rope
3
- Blanking plate
4
- Clamp
5
- Screw 6 x 25
6
- Screw 6 x 20
7
- Rear heat shield