Chapter 2. FAST DOME CAMERA SETUP
DIP Switch Setting
Camera ID Switch
Camera Function Switch
Alarm Mode Switch
Fan Power Switch
Chapter 2-1. Fan Power Switch
Chapter 2-2. Alarm Mode Switch
Chapter 2-3. Camera Function Switch
Turn the number 2 switch to ON position to activate the internal fan. This will maintain the
temperature inside and make the electric parts longer life.
Alarm Mode can be set as Lock or Release mode. Turn number 1 switch to ON position to
choose Release mode. Turn number 1 switch to OFF position to choose Lock mode.
Fast Dome has 6 alarm inputs and 1 output, which can be set either NC (normally close) or
NO (normally open) mode. Turn number 2 switch to ON position to choose NC mode.
Turn number 2 switch to OFF position to choose NO mode.
Turn number 1 switch to ON position for AGC function
Turn number 2 switch to ON position for BLC function
Turn number 3 switch to ON position for AWB function
Turn number 3 switch to OFF position for Manual White Balance (MWB)
When fast dome is set to MWB, turn number 4 switch to ON for Outdoor (color temp. 3200K)
or to OFF for Indoor (color temp. 6300K)
Page 2 of 12
IP Fast Dome Quick Installation Guide