background image

SGSM

The magnetic ring 

2

 is fixed to the drive shaft using 

three grub screws 5 type M4 x 5 min.

 (Figure 5).

4.3 Mounting tolerances

The acceptable gap 

D

 between the sensor 

1

 and the 

magnetic ring 

2

 is 

between 0.1 and 1.5 mm

.

The  sensor  

1

  and  the  ring  

2

  must  be aligned  as 

shown in Figure 6, the 

maximum lateral deviation 

is 1.5 mm

 on both sides.

WARNING

Prevent the sensor 

1

 and the magnetic 

ring 

2

 from coming into contact.

5 - Electrical connections

WARNING

Electrical connection has to be carried 
out   by   qualified   personnel  only, with 
power   supply   disconnected   and 

mechanical parts compulsorily in stop.

Function

M12 8-pin

M8 cable

0 VDC

1

Black

+VDC 

*

2

Red

A

3

Yellow

/A

4

Blue

B

5

Green

/B

6

Orange

not connected

7

White

not connected

8

Gray

Shielding

Case

Shield

*

 see order code

SGSM-

L

-

1

-… 

+VDC = +5VDC ± 5%

SGSM-

Y

-

2

-…

+VDC = +10VDC +30VDC

NOTE

All   sensors   can   provide   inverted 
signals.
A = A signal

/A   =   inverted   A   signal   (or   complementary   signal, 
typically referred to as A NOT)
The whole range of magnetic sensors provides A, /A, 
B, /B output signals. We recommend the inverted 
signals   always   to   be   connected   whenever   the 
receiving device can accept them. Otherwise each 
output has to be insulated singularly.

WARNING

Connecting   output   signals   together 
and/or   to   +VDC   or   0VDC   may   cause 
permanent damage to the sensor.

MAN SGSM I_E 1.5.odt

12

www.lika.it

www.lika.biz

Figure 5 - Fixing the magnetic ring

Figure 6 - Mounting tolerances

Summary of Contents for SGSM

Page 1: ...sicurezza o delle avvertenze specificate in questo manuale è considerato una violazione delle norme di sicurezza standard previste dal costruttore o richieste dall uso per cui lo strumento è destinato Lika Electronic s r l non si assume alcuna responsabilità per eventuali danni o lesioni derivanti dall inosservanza delle norme di sicurezza da parte dell utilizzatore 1 2 Avvertenze elettriche Effet...

Page 2: ...metallici nel caso in cui questo non sia possibile prevedere adeguati sistemi di pulizia es spazzole raschiatori getti d aria compressa al fine di evitare grippaggi tra sensore e anello 2 Identificazione Il dispositivo è identificato mediante il codice di ordinazione e un numero di serie stampati sull etichetta applicata al dispositivo stesso i dati sono ripetuti anche nei documenti di trasporto c...

Page 3: ...elle tolleranze di parallelismo tra sensore 1 e anello magnetico 2 Fissare il sensore 1 utilizzando due viti M4 di lunghezza minima di 20 mm passanti nei due fori presenti Le boccole di fissaggio sono predisposte per viti a testa cilindrica 3 tipo TCEI M4 x 20 su un lato e viti a testa svasata 4 tipo TSP M4 x 20 sull altro Le viti a testa cilindrica 3 consentono un minimo gioco per allineare il se...

Page 4: ...o VDC 2 Rosso A 3 Giallo A 4 Blu B 5 Verde B 6 Arancione non collegato 7 Bianco non collegato 8 Grigio Schermo Custodia Calza si veda il codice di ordinazione SGSM L 1 VDC 5VDC 5 SGSM Y 2 VDC 10VDC 30VDC NOTA Questo encoder prevede uscite complementari pertanto A canale A diritto A canale A negato complementare Nel caso in cui l elettronica di lettura fosse predisposta alla lettura differenziale s...

Page 5: ...è proporzionale allo spostamento meccanico con frequenza proporzionale alla velocità di rotazione dell anello magnetico L elettronica di conversione all interno del sensore trasforma l informazione del campo magnetico dell anello in un segnale elettrico equivalente a quello di analoghi sistemi ottici incrementali La frequenza dei segnali di uscita è proporzionale alla velocità di lettura mentre il...

Page 6: ...e magnetica es acciaio non amagnetico Durante il funzionamento il sensore è venuto ripetutamente in contatto con la superficie magnetica provocandone il guasto ispezionare la superficie attiva del sensore E stato provocato un cortocircuito sulle uscite oppure un inversione di polarità sulla alimentazione del sensore il sensore si brucia e risulta inutilizzabile Errore Il sistema fornisce misure in...

Page 7: ...SGSM MAN SGSM I_E 1 5 odt 7 www lika it www lika biz Pagina lasciata bianca intenzionalmente ...

Page 8: ...ezione 4 1 4 Nuovi collegamenti web 1 5 Revisione istruzioni di montaggio revisione generale Smaltire separatamente LIKA Electronic Via S Lorenzo 25 36010 Carrè VI Italy Tel 39 0445 806600 Fax 39 0445 806699 Italy eMail info lika it www lika it World eMail info lika biz www lika biz MAN SGSM I_E 1 5 odt 8 www lika it www lika biz ...

Page 9: ... use in explosive or flammable areas failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the equipment Lika Electronic s r l assumes no liability for the customer s failure to comply with these requirements 1 2 Electrical safety Turn OFF power supply before connecting the device connect acco...

Page 10: ...nstance brushes scrapers jets of compressed air etc are in place in order to prevent the sensor and the magnetic ring from jamming 2 Identification Device can be identified through the ordering code and the serial number printed on the label applied to its body Information is listed in the delivery document too Please always quote the ordering code and the serial number when reaching Lika Electron...

Page 11: ...anical system complies with the parallelism tolerances between the sensor 1 and the magnet ring 2 Fix the sensor 1 by means of two M4 20 mm min long screws inserted through the provided holes Bushings are designed to accept TCEI M4 x 20 cylinder head bolts 3 on one side and TSP M4 x 20 countersunk head bolts 4 on the other side Cylinder head bolts 3 allow a slight play useful for centring the sens...

Page 12: ...op Function M12 8 pin M8 cable 0 VDC 1 Black VDC 2 Red A 3 Yellow A 4 Blue B 5 Green B 6 Orange not connected 7 White not connected 8 Gray Shielding Case Shield see order code SGSM L 1 VDC 5VDC 5 SGSM Y 2 VDC 10VDC 30VDC NOTE All sensors can provide inverted signals A A signal A inverted A signal or complementary signal typically referred to as A NOT The whole range of magnetic sensors provides A ...

Page 13: ... as the frequency is proportional to the rotation speed of the magnetic ring As the sensor reads the magnetic ring whilst it turns it detects the displacement and issues an output signal equivalent to the one of an incremental encoder or a linear scale The output signal frequency is proportional to the measuring speed while the number of output pulses is proportional to the mechanical displacement...

Page 14: ...the sensor has been mounted incorrectly A magnetic part has been inserted between the sensor and the substrate Only non magnetic materials are allowed between the sensor and substrate The sensor touches the substrate because the tolerance gap between the sensor and the substrate is not met Check the sensor active side if damaged The sensor has been damaged by short circuit inversion of polarity or...

Page 15: ...SGSM MAN SGSM I_E 1 5 odt 15 www lika it www lika biz This page intentionally left blank ...

Page 16: ...or in section 4 1 4 New web links 1 5 Mounting instructions updated general review Dispose separately LIKA Electronic Via S Lorenzo 25 36010 Carrè VI Italy Tel 39 0445 806600 Fax 39 0445 806699 Italy eMail info lika it www lika it World eMail info lika biz www lika biz MAN SGSM I_E 1 5 odt 16 www lika it www lika biz ...

Reviews: