Standard External Trigger
In this mode, camera frames are generated using an external signal. When the input signals selected edge is
detected, the image sensor begins integration followed by image readout.
Figure 7.1: Standard External Trigger Mode
GenICam—Acquisition Control
Acquisition Mode
Single Frame
Trigger Selector
Acquisition Start
Trigger Mode
On
Trigger Source
Line 0
Trigger Activation
Rising or Falling edge
Trigger Delay
Adjustable
Exposure Time
Integration Time
Exposure Auto
Off