SHAREMIKE REGISTRATION (OTHER REGISTERED COMPONENTS IN PLACE)
(particularly valuable when Topcat is mounted in the ceiling or on the wall)
For users adding a Sharemike or replacing a lost or malfunctioning Sharemike.
1. Start with the Topcat plugged in and powered on. To verify it is powered on,
there will be a blue power light on the front of the Topcat.
2. If replacing a Sharemike, make sure the malfunctioning unit is powered off.
3. If a Flexmike is present, power it on and wait until it has a solid blue or red light (“Ready”).
4. Power on the new Sharemike. Both microphone 1 and 2 blue lights should start blinking.
5. Slide open the Sharemike battery compartment. The registration button is located below the battery on the left
side, marked REG.
8. After several seconds, the #2 light on the Topcat will turn solid and only the #2 light
on Sharemike will remain blinking, then turn solid.
9. The registration is complete. You can begin speaking into the new Sharemike to
verify there is audio.
10. Place system ID number (attached to the Topcat Daily Use Guide) on the new
Sharemike.
NOTE:
if at any point, the Topcat or Sharemike lights begin blinking rapidly, that
indicates a registration error. Turn the new Sharemike off and repeat steps 4-9.
Power On
Solid light
(Existing Flexmike)
6. Use another registered functional component (existing Flexmike, Sharemike,
or Media Connector) to trigger the registration function in Topcat.
(For the
purpose of these instructions, it is assumed that a Flexmike is the the existing
registered component.)
• Using a paperclip with the end straightened out
, press and hold the
registration button inside the registered Flexmike for 3 seconds.
• The 1 and 2 amber lights will begin blinking on the Topcat.
7. Briefly press the registration button on the Sharemike. The 1 and 2 lights
will start blinking alternately.
Topcat
Access
Blinking lights
Power On
Blinking lights
Sharemike
Registration
Button
Registration
Button
STANDARD REGISTRATION
Topcat
Access
Solid lights
SYS
TEM ID#
SYS
TEM ID#
SYS
TEM ID#
SYS
TEM ID#
SYS
TEM ID#
RETAIN EXTRA LABELS IN THE EVENT A COMPONENT IS REPLACED OR ADDED.
Ma
tch components
to this system ID#
Apply to system components to indicate which parts are registered
as a system. Keep registered items together when storing away.
Registration ID Labels
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
334-0162-02-00-01
10101
Topcat
Access
Solid light
TOPCAT ACCESS REGISTRATION GUIDE