STANDARD REGISTRATION
FLEXMIKE REGISTRATION (OTHER REGISTERED COMPONENTS IN PLACE)
(particularly valuable when Topcat is mounted in the ceiling or on the wall)
For users adding a second Flexmike or replacing a lost or malfunctioning Flexmike.
1.
Start with the Topcat plugged in and powered on. To verify it is powered on, there will
be a blue power light on the front of the Topcat.
2.
If replacing a Flexmike, make sure the malfunctioning unit is powered off.
3.
If a second Flexmike, Sharemike or Media Connector is present, power it on
and wait until it has a solid blue light (“Ready”). Power on the new Flexmike.
Both microphone 1 and 2 blue lights should start blinking.
7.
After several seconds, the number 2 light on the Topcat will turn solid and the 2 light
on Flexmike will remain blinking, then turn solid.
8.
The registration is complete. You can begin speaking into the new Flexmike to verify
there is audio.
9.
Place system ID number (attached to the Topcat Daily Use Guide) on the new
Flexmike.
NOTE:
if at any point, the Topcat or Flexmike lights begin blinking rapidly, that
indicates a registration error. Turn the new Flexmike off and repeat steps 4-9.
Power On
Solid light
(Existing Flexmike)
4.
Open the new Flexmike battery compartment and pull the battery out (leaving it
plugged in) to reveal the registration button.
5.
Use another registered functional component (existing Flexmike, Sharemike or
Media Connector) to trigger the registration function in Topcat.
(For the purpose of
these instructions, it is assumed that the #1 Flexmike is the functioning Flexmike
and we are registering the #2 Flexmike.)
• Using a paperclip with the end straightened out
, press and hold for 3
seconds the registration button inside the functioning Flexmike.
• This triggers registration in the Topcat and the Topcat’s 1 and 2 amber lights
will begin blinking.
6.
Briefly press the registration button on the new or replacement Flexmike. The 1 and 2 blue lights will start blinking alternately.
Topcat
Access
Blinking lights
Power On
Blinking lights
(NEW Flexmike)
Registration
Button
Topcat
Access
Solid lights
SYS
TEM ID#
SYS
TEM ID#
SYS
TEM ID#
SYS
TEM ID#
SYS
TEM ID#
RETAIN EXTRA LABELS IN THE EVENT A COMPONENT IS REPLACED OR ADDED.
Ma
tch components
to this system ID#
Apply to system components to indicate which parts are registered
as a system. Keep registered items together when storing away.
Registration ID Labels
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
00-01
334-0162-02-00-01
10101
TOPCAT ACCESS REGISTRATION GUIDE
Topcat
Access
Solid light