OUTPUT CHANNEL CONNECTIONS 
 
The RD-121 can be supplied with one of several rear panel output options.  Channel output connections are 
according to the the rear panel selected.  Channel connections generally proceed from left to right (if you are 
facing the rear of the unit).  Channel “A” will be on the left end.  Connections for load Neutrals are provided. There 
is also a ground lug terminal to be used for your load circuits grounds. 
 
CONTROL SIGNAL CONNECTIONS 
 
A control signal enters the RD-121 through connectors on the rear of the unit. If you are using the 3 pin multiplex 
protocol ("LMX" or compatible), plug the control cable into the 3 pin "XLR" connector. If you are using the DMX-
512 protocol, plug your 5 pin DMX control cable into the 5 pin to 9 pin adapter supplied with the RD-121 and plug 
the 9 pin connector into the upper 9 pin connector on the rear of the dimmer. In either case, the lower 9 pin 
connector and the ribbon cable jumper that is supplied can be used to connect from the lower connector of the 
first dimmer into the upper connector of the next dimmer and so on. See the included drawings at the back of this 
manual for clarification.  The RD-121 is shipped with the power supply set to p15 volts DC console power 
when using the 3 pin multiplex protocol.  Note that the DMX-512 protocol does NOT provide a means for console 
power via the control cable. Systems using the DMX protocol must have console power supplied by other means.   
 

SETUP 

 
The RD-121 has a front panel LCD display and operator controls.  The display indicates dimmer status 
information and is used with the operator control buttons to set up and monitor dimmer operation.  A menu system 
is used to access the various features of the RD-121.  During normal dimmer operation the display shows the 
current intensity setting for each channel and indicates what type of dimmer control is in affect.  This is called the 
STATUS DISPLAY and is shown in the diagram below. 
 
 

STATUS DISPLAY AND OPERATOR CONTROLS 

 

 
 
 
 

Summary of Contents for RD-121

Page 1: ...RD 121 RACK MOUNT DIMMER OWNERS MANUAL REVISION 1 2 02 28 2005 www lightronics com Lightronics Inc 509 Central Drive Virginia Beach VA 23454 757 486 3588...

Page 2: ...IMMER CHANNELS 5 TO SET CHANNELS TO DIM OR NON DIM 5 MANUAL OPERATION 5 NORMAL OPERATION 6 INTERNAL SCENE OPERATION 6 TO SAVE A SCENE 6 TO ACTIVATE A STORED SCENE 6 NOTES ABOUT INTERNAL SCENE 7 CHASER...

Page 3: ...r to determine the operating frequency One or more RD 121 dimmers are to be installed into a standard 19 equipment rack with provisions for connection to an appropriate electrical service in accordanc...

Page 4: ...tor into the upper 9 pin connector on the rear of the dimmer In either case the lower 9 pin connector and the ribbon cable jumper that is supplied can be used to connect from the lower connector of th...

Page 5: ...itself TO ASSIGN DIMMER CHANNELS 1 Press the MENU once to enter the patch mode The display will indicate PTCH 2 Push SELECT The left display bargraph channel for dimmer channel A will flash and the c...

Page 6: ...panel SELECT button until you see the front panel display appears as shown below Scene Save 01 You will have to hold the button down for about 6 seconds 3 Push SELECT The display will show the message...

Page 7: ...e chase The RD 121 may be set to begin chaser functions at power up or in response to a remote switch A bounce option can be imposed on a chase pattern This results in a pattern which runs in its norm...

Page 8: ...RANDOM 6 CHANNEL BUILD PROGRAMMABLE CONTROLLING CHASER CHARACTERISTICS You can control seven characteristics of a chase pattern These controls are described as follows Chase Rate The duration of each...

Page 9: ...nnel SELECT Advance to Next Channel Set Flashing Channel to Relay Dimmer Mode RLY Relay Mode DMR Dimmer Mode SELECT Advance to Next Channel Set Remote Switch Function Not Used Chaser Scene SELECT Exit...

Page 10: ...en channel to be on for a chase step then the channel must be set to greater than 50 intensity Note that the overall intensity of the whole chase pattern may be set using the menu system 2 Press and h...

Page 11: ...nsole Verify the loads and their connections OWNER MAINTENANCE There are no user serviceable parts inside the unit The best way to prolong the life of your unit is to keep is cool clean and dry It is...

Page 12: ...Supplied with each unit Ribbon Cable Jumper Supplied with each unit 3 Pin Multiplex Protocol Input 3 Wire Control Cable Console using 3 pin multiplex protocol DMX 512 CONNECTIONS MULTIPLEX CONNECTIONS...

Page 13: ...82 AND RD 121 DMX 512 CONNECTOR 5 PIN MALE XLR Used on adapter cable MULTIPLEX LMX CONNECTOR 3 PIN MALE XLR Used on rear of chassis 2 1 3 NOT USED 5 1 DMX DATA NOT USED 4 3 2 COMMON CONSOLE POWER DMX...

Page 14: ...s not cover loss or damage direct or indirect arising from the use or inability to use this product F Lightronics reserves the right to make any changes modifications or updates as deemed appropriate...