PHOTOMETRIC MEASUREMENTS 

LED array will either turn on or off based on the DMX-
KEEP setting when DMX signal is lost.  

 
BK-LIGHT: ON/OFF 

 

The backlight for the  LCD display remains on  at all 
times if this function is set to ON. When BK-LIGHT  is 
set to OFF, the backlit display will turn off 30 seconds 
after the last button push on the control panel.  
 

NOW TEMP 

 

Provides operating temperature in ºC. 

 

MAINTENANCE AND REPAIR 

 
TROUBLESHOOTING 

 

Fixture will not power up. 

 

Check that you have power applied to the 
unit. 

 

Check the fuse located on the back panel 
of the fixture.  

 
Unable to control fixture. 

 

Check that the LCD display currently 
indicates “DMX-addr”. 

 

Check the LCD display on the fixture, if 
there is a ‘V’ after the DMX value, a valid 
DMX signal is present. If an ‘x’ is showing, 
then a valid DMX signal is not present. 

 

Verify the fixture is properly addressed. 

 

Check the DMX control cable for continuity 
and polarity. 

 

Remove the fixture from the DMX chain 
and all other DMX devices.  

 

Check the address settings or patch at the 
controller. 

 

CLEANING 

 

DISCONNECT THE POWER CORD BEFORE 
HANDLING THE UNIT.

 

 

A mild detergent can be used sparingly if needed. 
Apply to cloth first, do not apply detergents directly to 
fixture.  Do not use chemicals or solvents when 
cleaning the fixture.  Ensure the unit is dry before use. 

 
REPAIR 

 

The only FXLE3030W user serviceable part is a 5 mm 
x 20 mm externally accessible fuse on the rear panel. 

 
DISCONNECT THE POWER CORD BEFORE 
CHECKING OR REPLACING THE FUSE. 

 

Replace fuse ONLY with 5.0 Amp, 250VAC, fast acting 
fuse.  Requires #2 Phillips screwdriver, use caution to 
not overtighten.  
 

 
 
 
 
 

 
Internal service on the unit by other than Lightronics 
authorized agents will void the warranty. 
 
If service is required, contact the dealer from whom 
you purchased the item, or contact the Lightronics 
Service Department, 509 Central Drive, Virginia Beach, 
VA 23454.  Tel: 757 486 3588. 
 

WARRANTY INFORMATION AND 
REGISTRATION – CLICK LINK BELOW 

 

www.lightronics.com/warranty.html 

 

 
 
 

FXLE3030W 

10 Foot 

20 Foot 

30 Foot 

 

Beam 

(feet) 

FC 

Lux 

Beam 

(feet) 

FC 

Lux 

Beam 

(feet) 

FC 

Lux 

19° 

2.5 

2150 

23200 

537.5 

5800 

7.5 

239 

2578 

26° 

4.75 

1039 

10960 

279 

2950 

13.5 

125 

1345 

36° 

6.33 

533 

5740 

12.6 

143 

1545 

19 

65.4 

704 

50° 

279 

3000 

18 

75 

807 

27 

34 

368 