background image

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    Page  2 of  3 

 

 

 

 

 

 

 

 

 

 

 

 

FXLE3030W LED FIXTURE 

 

Version 1.1   

 

 

 

 

 

 

 

 

 

OWNER’S MANUAL   

 

 

 

 

 

 

 

 

      02/08/2022 

www.lightronics.com 

Lightronics Inc.   

 

 

 

 

 

 

 

509 Central Drive, Virginia Beach, VA  23454 

 

 

 

 

 

 

 

   757 486 3588

 

DMX CONNECTIONS 

 

A system using DMX control should be connected as a 
chain of devices. In other words,  the control signal 
cable should originate at  the controller to the first 
receiving device and then to others in one  continuous 
chain. An optically isolated DMX splitter is recommend 
when installing the FXLE3030W  in a system with 
various other DMX devices. 
 
The FXLE3030W has a DMX IN and a DMX OUT 
connector  which are  used to connect the DMX data 
chain. The control cable can  NOT be split into a Y or 
multiple run/star arrangement with a cable running 
directly from the controller to each receiving device. 

 
DMX CONNECTOR PIN ASSIGNMENTS 

 

Predominantly two connectors are used for connecting 
fixtures and other DMX devices to a DMX control 
chain. They are both “XLR type”  connectors.  Some 
units use 3 pin connectors,  others  use 5 pin 
connectors. The FXLE3030W

 

receives a DMX signal 

on the 3 pin MALE connector on the rear of the unit.  
The 3 pin FEMALE connector is used to connect to the 
next DMX device on the control chain. 
 
If your console uses a 5 pin XLR connector, an adapter 
cable can be purchased or fabricated to accommodate 
this conversion.  The  following table  shows the pin 
assignments for both 3 pin and 5 pin XLR

 

connectors:

 

 
 
 
 
 
 
 

 

 
DMX TERMINATION 

 

It is recommended that a DMX  data  chain be 
terminated at the last receiving device on the chain.  
This is done by installing a commonly available 1/4 
Watt, 120 Ohm resistor across the DATA -  and DATA 
+ wires at the last device.  If you have only a few 
fixtures  installed  very close together and with  a short 
run of DMX cable  to the controller,  then you may be 
able to operate without the terminator.  
 

OPERATION 

 

A  display and user interface is located  on the back of 
the unit.  This interface  is used to set the operating 
options  and settings.  It consists of a backlit  LCD 
display and four buttons (MODE,  DOWN,  UP, and 

ENTER).

 

 
 
 

 
 
 
 
 
 

 
Use  MODE  to scroll through  the  available  choices.  
Push ENTER when you reach the option you want to 
check or set.  The current setting for the option will be 
shown.  Push  UP and DOWN until you reach the 
desired setting or menu then push ENTER to invoke 
the new setting.  Push  ENTER  to exit from the sub 
menus. 

 
DMX OPERATION 

 

Use the DMX-Addr  menu to set the unit DMX starting 
address.  The range is 001  -  512.  A ‘V’  will be 
displayed  if  a valid DMX  signal  is present, an ‘x’ 
represents that no valid DMX signal is present. 
  

For this fixture to operate in DMX mode, the mode 
needs to be set for “DMX-Addr” on LCD display by 
pressing the MODE button. 

 

The fixture has 2 DMX modes. 1  channel and 2 
channel: Channel 2 is not active in 1 channel mode.  

 

CHANNEL 1: 

Fixture Intensity (000 - 255) 

CHANNEL 2: 

Strobe Control (000 - 127, 128-255) 
000 is Strobe OFF, starts slow and 
increases to fastest at 127. From 128-
255 pattern transitions to short light 
pulses with longer duration between 
pulses as value rises from 128 to 255.  
 

STAND ALONE MODE  

 

You can operate the unit  manually using the R-
DIMMER  & P-STROBE menu.  Push  the UP and 
DOWN buttons to change the level, then p ush ENTER 
when done.  The range is 000 -  255 (See above for 
values).  
 
If connecting multiple FXLE3030W fixtures together in 
stand-alone mode, set the DMX address on additional 
units to d001 to follow the main fixture. 
 

DMX-KEEP: ON/OFF  

 

The DMX-KEEP mode determines the characteristic of 
the fixture upon the loss of the DMX input signal. The 

PIN # 

SIGNAL NAME 

DMX COMMON 

DMX DATA - 

DMX DATA + 

NOT USED 

NOT USED 

MODE 

ENTER 

UP

 

DOWN 

CONTROL PANEL 

Reviews: