background image

0.0

45.0

90.0

FLUX

0

8537

8537

8537

5

8532

8393

8265

799

10

8424

7992

7495

15

8225

7324

6543

2058

20

7938

6549

5635

25

7602

5743

4703

2720

30

7179

4938

3863

35

6679

4141

3190

2797

40

6124

3358

2794

45

5510

2724

2509

2554

50

4842

2270

2174

55

4153

1959

1956

2096

60

3424

1625

1630

65

2666

1355

1138

1432

70

1943

979

750

75

1218

542

391

649

80

539

220

70

85

53

0

0

62

90

0

0

0

Surface/Pendant Mounted Fluorescent

TriLyte FH4

Page 2 of 2

17" Narrow Body, 48 or 96" Length

2, 3 or 4 Lamp T5 and T8

Job Information

Type:

Ordering Information

Explanation of Catalog Number. Example: FH4C4DXX454120PV

Options/Accessories

Emergency Power Pack:

Factory installed emergency power pack includes charger

and inverter concealed in fixture channel. Upon lost of AC power, operates one lamp
at high lumen output for a period of 90 minutes. Catalog Number:

LP600

(std. Bodine LP600).

Electrical Wiring Options:

Consult factory.

Stem and Canopy Kits:

Suspend luminaire 12", 18", 24", 36" and 48" from surface.

(Four per luminaire is recommended. Catalog Number: 

ASC6 CSP

(6"),

ASC12 CSP

)12"), 

ASC18 CSP

(18"), 

ASC24 CSP

(24").

Chain Suspension Option:

24" Chain Suspension Kit (Two per fixture is required).

Catalog Number:

EE9HC

.

Sensors:

Order Catalog Number: 

FH360

for Line Voltage Sensor. (Sold separately /

Field installed).

Specifications

Materials: Chassis parts

are die-formed code 20 gauge cold rolled steel.

Finish: Chassis exterior

– post painted in a baked polyester powdercoat

finish. 

Cavity

– white baked polyester powdercoat, minimum reflectance 86%.

Specifications (continued)

Reflector

– contoured or flat design specular reflector. 95% reflectivity.

Electrical:

Thermally protected class “P’ ballast C.B.M. approved, non PCB. If

K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.

Labels:

I.B.E.W./UL and ULc Listed.

FH

TriLyte

FH4:

Heavy Duty

Surface

Luminaire

Fixture

Width

4

=48"

8

=96"

Reflector*:

C

= Contoured

Specular

S

= Flat Specular

W

= Flat White

*Not available

in 2 lamp option
with contoured
specular reflector

D

Light

Direction:

D

=Direct

4

Fixture

Width:

4

=17"

Model No. FH4C4DXX454120PV

LER = FP - 67.1

IW -23.6

BF - 1.0

Comparative yearly lighting energy cost per

1000 lumens = $3.57

Report Number: LSCA590
Catalog Number: FH4C4DXX454120PV
Lamps: 54W T5HO
Luminaire: Surface/pendant, slim profile
with contoured specular reflector
Ballast: ICN-4554-90C-2LS
Report is based on 4400 Lumens per lamp.

Efficiency: 86.2%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

0.8

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

CANDELA DISTRIBUTION

0

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

18682.

9269.

8539.

55

17358.

8220.

8205.

65

15121.

7712.

6479.

75

11286.

5023.

3636.

85

1467.

0.

0.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 96 92 89 87 85 83 84 82 80

0

2 88 83 78 78 74 71 76 72 70

0

3 82 74 68 71 66 62 68 64 61

0

4 76 67 60 64 59 54 62 57 54

0

5 70 60 53 57 52 47 56 51 47

0

6 65 55 48 52 46 42 51 46 42

0

7 60 50 43 48 42 37 46 41 37

0

8 56 45 38 43 37 33 42 37 33

0

9 52 41 34 39 33 29 38 33 29

10 48 37 31 36 30 26 35 30 26

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

5576

31.69

36.77

0

0-

0

40

8373

47.58

55.21

0

0-

0

60

13023

74.00

85.87

0

0-

0

90

15166

86.17

100.00

40-

0

90

6792

38.58

44.79

60-

0

90

2142

12.17

14.13

90-180

000

0

.00

00

.00

0

0-180

151.66

86.17

100.00

ZONAL LUMEN SUMMARY

Lightolier 

a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 a Genlyte company

Section 7/Folio Q40-10

Voltage:

120, 277 or 

UNV

UNV

=120-277

Lens Shielding:

WW

= White Wire-

guard/No Lens

VA

= White  Wire-

guard/Pattern 
12 .095"

V

I

= White Wire-

guard/Pattern 
12 .125"
nominal lens

XX

= No Shielding

Lamp

Quantity:

2

=2 Lamp

3

=3 Lamp

4

=4 Lamp

Lamp:

32

=32 Watt T8 

28

=28 Watt T5

54

=54 Watt T5HO
(Nominal 48") 

Ballast Type:

<

20THD

<

10THD

1-2 Lamp Elec. T8

SO *

H

I

*

*

1-3 Lamp Elec. T8

O3 *

H3 *

*

1-4 Lamp Elec. T8

O4 *

H4 *

*

1-2 Lamp & 1-4 Lamp Elec. T8

O5 *

H5 *

*

2-3 Lamp  Elec. T8

O6 *

H6 *

*

1-4 Lamp Outside, 1-4 Lamp

Inside Elec. T8

O7 *

H7 *

*

1-2 Lamp Elec. T5

P

I

1-2 Lamp Elec. T5, 28W or 54W

PG ††

1-3 Lamp Elec. T5, 54W

PU ††

1-4 Lamp Elec. T5, 54W

PV ††

1-2 Lamp & 1-4 LampElec. T5, 54W

P6 ††

1-3 Lamp (for Lamps 1, 3, 5) &

1-3 Lamp (for 2, 4, 6) Elec. T5, 54W

P7 ††

1-4 Lamp Outside Lamps & 1-4

Lamp Inside Lamps  T5, 54W

P8 ††

*Instant Start Standard (120, 277 or 

UNV

)

†Instant Start Standard (120, 277)

††Program Start Rapid Start (

UNV

only)

Ballast Type:

NOTE:

See Above

Reviews: