LIGHT PROGRESS 

 

 

 

 

 

 

 

 

 

    DIRECT-H-K [eng]

 

 

 

gen-2021 

 

Pag. 4/16

 

 

DEVICE DESCRIPTION 

 
The 

UV-DIRECT 

series includes germicidal devices using UV-C ultraviolet rays with 

direct radiation 

that sterilize the 

air  and  surfaces.  The  UV-C  lamps,  with  emission  peak  at  235.7  nm.  (nanometers),  have  strong  germicidal  power 
against all micro-organisms (mold, bacteria and viruses).  
 
The 

UV-DIRECT 

...

line is destined to be recessed in the false-ceiling (or recessed in the wall) allowing finishing on 

the same level, with minimal protrusions.  
The shaped case consists of a box of stainless steel AISI 304with a screen in mirror-shined aluminium that increases 
yield, by reflecting the part of UV-C rays that would otherwise be dispersed away from the useful direction.  
The device consists of a case inside of which is enclosed a waterproof channel in aluminium containing all the electron-
ic power parts, with IP 55 degree of protection.  
The UV-C lamps protected by a STAINLESS-STEEL grid. The device is supplied complete with a 3x1 mmq of 2.5 m. 
cable without power plug.  
 

OPERATION 

 
The devices of the UV-DIRECT series can be installed in any type of environment to obtain deep disinfection of air and 
surfaces, even those that are difficult to reach with traditional cleaning systems. When the  lamps ON there is a strong 
reduction of microbes present in the ambient air and on the surfaces reached by UV rays. For example, in 8 minutes at 
a distance of 3 m. from the device, there is a 99% reduction of bacteria Bacillus, Coli, Clostridium, Legionella, Vibrio, 
Salmonella, Pseudomonas, Staphylococcus, Streptococcus, etc.  
Thanks to the natural circulation of the air, even the microbes located in hidden areas are continuously pulled toward 
the area of the U.V. rays so that their overall level decreases progressively.  
Use is allowed  only with no personnel present or if contained within adequately screened areas. The device must be 
switched on for 2 ± 3 hours during the hours of work breaks; for example, by means of a programming clock, night op-
eration can  be  managed in the hours immediately prior to the entry of the operators, to allow  entry in a freshly disin-
fected site. Operation can also be managed by means of appropriate power units that, especially in case of installation 
of various devices, can manage other operations, such as:  

Power timing

; it is possible to regulate the duration of treatment by means of a regulatable timer.  

Managing entries

; a security system turns out the lights in case of entry of staff.  

Remote and local alarms

 in case one or more lamps switch off, due to wear, a spy light will light up on the front panel 

and it will be possible to use a contact to signal the failure remotely.  

Counter

 to manage the proper replacement of lamps.  

 

BENEFITS AND ADVANTAGES 

 
a)  DEEP AND CONTINUOUS DISINFECTION  
This device can be switched on continuously without people being present (i.e. during the night for 2-3 hours). The dis-
infection of the air, the machinery, and everything that is contained inside the room allows beginning the work day in 
ideal hygienic conditions. In this way, the level of microbial load in one site is maintained constantly low.  

 

b)  PHYSICAL ACTION AND ECOLOGICAL PROTECTION  
Treatment with UV-C rays is purely physical, always allowing treatment with the same efficiency; there is no danger of 
overdosing with UV rays in the air. In contrast, many chemical treatment methods involve the use of products that are 
risky and difficult to biodegrade, with consequent hazards to human health; besides, the use of chemical products, in 
contrast to UV-C rays, could develop resistant microbial forms.  

 

c)  PRACTICALITY AND ECONOMY  
Treatment is immediate and ready to use. Maintenance is minimal with low costs of both energy consumption and of 
maintenance.  

 

d)  IMMEDIATE EFFECT 
Effective treatment (99.9% bacteria reduction) takes just a few minutes.  

 

e)  NO CHEMICAL/PHYSICAL CHANGES  
Treatment is cold and dry; it causes no organoleptic or qualitative changes in the food.  

 

f)  NO DANGER OF DISPERSION OF GLASS  
With the special UVLON® protection, there is no danger of dispersion of glass fragments resulting from any breakage 
of UV-C lamps. 

Summary of Contents for UV-DIRECT

Page 1: ...LIGHT PROGRESS DIRECT H K eng gen 2021 Pag 1 16 UV DIRECT Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV DIRECT E40H K NX UV DIRECT E75H K NX...

Page 2: ...re maintenance or cleaning ensure that the appliance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in c...

Page 3: ...it must follow the device in case of passage of property and accompany the device until its demolition To request the instruction manual updated and to ask all other information needed it s possible...

Page 4: ...ple by means of a programming clock night op eration can be managed in the hours immediately prior to the entry of the operators to allow entry in a freshly disin fected site Operation can also be man...

Page 5: ...ng and please be careful not to damage the con tents when using sharp blades or cutters to open the box Remove the unit from the box then inspect it immediately to ensure that no damage has occurred d...

Page 6: ...te them uniformly in the environment to avoid the hidden areas such as the corners it should allow all the air to be treated These models can be mounted on the wall and still comply with the regular d...

Page 7: ...the hole as shown in Figure 3C The ceiling may have a thickness from 1 mm up to 40 mm Fig 3C Fully open the locking brackets Insert the unit into the hole in the ceiling initially at one side then pas...

Page 8: ...CTIONS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that the device will be install...

Page 9: ...m contact can be powered by max 500mA of current and 24V of tension and can be connected to an electronic panel as MASTER ST control unit For this models see the numbering of the wires on the table be...

Page 10: ...ends and pull it in a direction parallel to the tube Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING UV LAMP See MAINTENANCE BALLAST All UV DIRECT models are supplied with electroni...

Page 11: ...ainless steel AISI 304 All the used materials are tested for resistance to intense UV C rays Waterproof and dust proof IP 55 Powered with electronic ballasts specific for UV C rays lamps Reflector in...

Page 12: ...request the return merchandise authorization RMA sending an email to in fo lightprogress it or calling the number 39 0575 749255 Once you receive the module it has to be filled up in every part and s...

Page 13: ...hinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1 Gene...

Page 14: ..._____________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ___________________...

Page 15: ...____________________________________________ ____________________________________________________ ____________________________________________________ _________________________________________________...

Page 16: ...g gen 2021 Pag 16 16 Loc San Lorenzo 40 52031 ANGHIARI AR ITALIA TEL 0575 74 92 55 FAX 0575 78 99 29 PRODUCTION ANGHIARI Loc San Lorenzo 40 CASTIGLION F NO Loc S Antonino 40 Http www lightprogress it...

Reviews: