background image

110  vOLT CORD-CONNECTED 15 AMP MODELS: 

• 

The GFCI is located at the end of the power cord. Before each use, with the unit operating, push 

the TEST button. The unit should stop operating and the GFCI power indicator will go out. Wait 30 

seconds and then reset the GFCI by pushing the RESET button. The GFCI power indicator will turn 

on, restoring power to the spa. If the interrupter does not perform in this manner, there may be an 

electrical malfunction and with it, the possibility of an electric shock. Disconnect the power until the 

problem has been corrected. 

NOTE: This will reset the filter cycle.

230 VOLT, PERMANENTLY iNSTALLED MODELS: 

• 

A ground terminal is provided on the control box. To reduce the risk of electric shock, connect this 

terminal to the grounding terminal of your electrical service or subpanel with a continuous green, 

insulated copper wire. The wire must be equivalent in size to the circuit conductors supplying the 

equipment. In addition, a bonding terminal (pressure wire connector) is provided on the outside of 

the control box for bonding to local ground points. To reduce the risk of electric shock, this connector 

should be bonded with a No. 8 AWG (8.4 mm

²

) solid copper wire to any metal ladders, water pipes, 

or other metal within 5 feet (1.5 m) of the spa to comply with local requirements. The means of 

disconnection must be readily accessible, but must be installed at least 5 feet (1.5 m) from the spa.

• 

Your spa requires a suitably rated circuit breaker to open all ungrounded supply conductors.

• 

Your spa must have a ground fault circuit interrupter in an electrical subpanel. Before each use of 

the spa and with the unit operating, push the TEST button on the breaker. The switch should click 

over to the “Trip” position. Wait 30 seconds and reset the GFCI breaker by switching it completely 

off and then completely on. The switch should then stay on. If the interrupter does not perform in 

this manner, it is an indication of an electrical malfunction and the possibility of an electric shock. 

Disconnect the power until the fault has been identified and corrected.

 IMPORTANT:

 Failure to wait 30 seconds before resetting the GFCI may cause the spa’s Power 

Indicator (on the control panel) to blink. If this occurs, repeat the GFCI test procedure.

   

DANgER: RiSk OF ELEcTRicAL ShOck

• 

Install spa at least 5 feet (1.5 m) from all metal surfaces. A spa may be installed within 5 feet of 

a metal surface if each metal surface is permanently connected by a minimum No. 10 AWG solid 

copper conductor attached to the wire ground connector on the terminal box that is provided for this 

purpose if in accordance with National Electrical Code ANSI/NMFPA70-1993.

• 

Do not permit any electrical appliances, such as a light, telephone, radio, or television within 5 feet 

(1.5 m) of a spa. Failure to maintain a safe distance may result in death or serious personal injury 

due to electrocution if the appliance should fall into the spa.

• 

Install your spa in such a way that drainage is away from the electrical compartment and from all 

electrical components.

DO:

• 

Be sure your spa is connected to the power supply correctly - use a licensed electrical contractor.

• 

Disconnect the spa from the power supply before draining the spa or servicing the electrical 

components.

• 

Test the Ground Fault Circuit Interrupter(s) before each use.

DON’T:

• 

Use the spa with the equipment compartment door removed.

SAFETY INFORMATION

2

Summary of Contents for LS100DX

Page 1: ...LS100DX LS600DX OWNER S MANUAL 110V 230V Models...

Page 2: ...h Height Dry Weight Electrical Specs 60Hz LS100DX 4 person 5 2 5 10 34 270 lbs 110V 9a LS200DX 4 person 6 5 5 6 29 244 lbs 110V 9a LS350DX 5 person 6 0 6 9 34 351 LBS 110V 9a LS400DX 5 person 6 3 6 3...

Page 3: ...ter Cycles 13 Operational Modes 13 SMART WINTER MODE 13 Diagnostic LCD Message 14 component operation Spacomponent operation 15 Fill Up and Start up instructions FILLING THE SpaWITH WATER 16 applying...

Page 4: ...hildren are careful when entering or exiting the spa DON T Allow children to climb onto the spa cover Allow children to have unsupervised access to the spa Avoiding the risk of electrocution Risk of e...

Page 5: ...ore each use of the spa and with the unit operating push the TEST button on the breaker The switch should click over to the Trip position Wait 30 seconds and reset the GFCI breaker by switching it com...

Page 6: ...spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving components Increased side effects of medication The use of drugs alcohol or medication before or duri...

Page 7: ...re with an accurate thermometer Test the water with your hand before entering the spa to be sure it s comfortable SAFETY SIGN A SAFETY SIGN in the owner s package The sign which is required as a condi...

Page 8: ...change clothes or a house entry near the spa is convenient A warmer climate may require shade from the hot sun Consider placement of trees shrubs patio cover or perhaps a gazebo structure to provide...

Page 9: ...rborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area An architect can help to determine if more ventila...

Page 10: ...ment Remove 1 vertical slat and 3 screws on each side of Equipment Access Panel Door Remove 6 screws from Equipment Access Panel Door to remove door Remove screws from Black ABS Door if your spa has v...

Page 11: ...re and attach it to the grounding lug on the power pack located in the equipment compartment 2 Only a licensed electrician may install power to the spa 3 Power supply installation must include a suita...

Page 12: ...HN copper core wire only All wiring must be copper to ensure adequate connections Do not use aluminum wire CAUTION WARNING SHOCK HAZARD No User Serviceable Parts Do not attempt to service any electron...

Page 13: ...t Installation permanently connected The LS600DX requires a 230 volts 32 amp service 2 hot wires a neutral wire and a ground wire When the spa is powered up the heater will provide approximately 4000...

Page 14: ...dicated and should not be shared with any other appliances The power supply must be hard wired into the power pack White Neutral Wire that is connected to Spa Neutral goes HERE 230V Wiring Instruction...

Page 15: ...600DX model firmly press the Jets button once to activate the low speed of the pump and again for the high speed Firmly press the Jets button again to turn off the pump If left running the low or high...

Page 16: ...F To enter the programming screen and toggle between Standard and Economy Mode the following is required 1 Press and hold the Light button for 5 seconds 2 Press the Light button several times until E...

Page 17: ...ater to cool down to a lower temperature Call your dealer or service supplier if problem persists UPL No low level configuration software has been installed into the system Call your dealer or service...

Page 18: ...ill increase or decrease the effects of any jets not in the closed position OZONE GENERATOR The ozone system greatly enhances the quality of the spa water when used to supplement the spa owner s regul...

Page 19: ...uce the amount of water you normally have in the spa To prevent the water from hitting your topside control or flowing over the top edge of the spa Additionally failure to keep enough water in your sp...

Page 20: ...CALCIUM HARDNESS It is important to bring the calcium reading between 100 250 PPM If the reading requires adjustment it should now be corrected If the water is too soft a low reading calcium hardness...

Page 21: ...g it out of the spa requires many turns Rinse cartridge using a garden hose Rotate and separate filter pleats while spraying water to remove all dirt and debris possible Let filter dry and look for ca...

Page 22: ...f the foam inserts This will not be covered under warranty CABINET CARE Little maintenance is required to keep your spa cabinet looking good Spa cabinet product should be cleaned as needed to remove d...

Page 23: ...Water left in the lines might freeze and damage the lines and jets 1 It will be necessary to remove all water from the interior plumbing 2 Remove the floating weir basket and filter cartridge Clean t...

Page 24: ...ove the gray filter ring 4 Check for dirty filter Clean if necessary 5 Make sure all jets are in the open position turn counterclockwise WATER IS TOO HOT 1 Check desired temperature on topside control...

Page 25: ...ck LS600DX 303532 EQUIPMENT PACK LS100DX LS450DX 303046 3 0 hp PUMP LS600DX 230V 2SPD 303001 1 0 hp PUMP LS100DX LS450DX 115V 2SPD 303535 4 BUTTON TOPSIDE CONTROL PANEL 303298 ROUND FILTER WEIR 303299...

Page 26: ...23...

Page 27: ...24...

Page 28: ...Part 303557 14 Rev D 6 14...

Reviews: