background image

13

CONTROL PANEL OPERATION

ADJUSTiNg PRESET FiLTER cYcLES

Filter duration is programmable between 0 and 6 hours in 30 minute increments (0.5 hours) for 

both filter cycles. To program the cycle times: 

1.  Press and hold 

light

 button for 5 seconds until F1 is displayed. 

2.  Press the 

Plus

 or 

Minus

 button to adjust the cycle time for F1.

3.  Press the 

light

 button to store the F1 cycle and move to the F2 cycle. 

4.  Press the 

Plus

 or 

Minus

 button to adjust the cycle time for F2.

5.  Wait 15 seconds to allow the exit timer to expire and store the setting.

IMPORTANT:

 To reset the first filter cycle start time, skip step 5 and continue pressing the 

light

 

button until the actual temperature is displayed. Powering down of the spa will also reset the first 

filter start time.

FiLTER cYcLE SUSPENSiON: 

The filter cycle will be suspended every time a jet pump or 

light is activated manually during the filter cycle time. The suspension will end 10 minutes after the 

completion of the manual use. 

OPERATiONAL MODES

The Standard Mode is the default operational mode preset from the factory. 

STANDARD MODE:

 Is programmed to maintain the desired temperature. 

EcONOMY MODE (LS600DX MODEL ONLY): 

The spa will heat normally during the filter 

cycle; outside of the filter cycle, the set point will be lowered by 20°F. To enter the programming 

screen and toggle between Standard and Economy Mode the following is required:

1.  Press and hold the 

light

 button for 5 seconds

2.  Press the 

light

 button several times until EP 0 or EP 1 is displayed.

3.  Use the 

Plus

 or 

Minus

 button to choose between Standard and Economy Mode.  

EP 0 = Standard Mode and EP 1 = Economy Mode.

4.  Wait 15 seconds to allow the exit timer to expire and store the setting.

OFF MODE: 

This mode allows you to stop all spa functions for 30 minutes to perform quick 

spa maintenance To place the spa in OFF MODE, press and hold the jets button for 5 seconds. 

The display will toggle between OFF and water temperature when in the OFF MODE. To stop the 

OFF MODE before the 30 minute cycle time is complete, simply tap (short press) the jet button.

FAhRENhEiT/cELSiUS SETTiNg 

To Change water temperature display to either Fahrenheit or Celsius, press and hold 

light

 

button for 5 seconds until F1... is displayed. Press the 

light

 button several times until F or C 

is displayed. Press the 

Plus

 or 

Minus

 button to change. Wait 15 seconds to allow the exit timer to 

expire and store the setting.

SMART WiNTER MODE

The Smart Winter Mode is used to prevent water from freezing in the plumbing of the spa. As soon 

as there is a risk of freezing, this protection kicks in. The SWM protection will turn back off only 

after 24 hours without a risk of freezing. During this 24 hour period, the Smart Winter Mode icon 

remains on; the icon blinks when the purge is active.

Summary of Contents for LS100DX

Page 1: ...LS100DX LS600DX OWNER S MANUAL 110V 230V Models...

Page 2: ...h Height Dry Weight Electrical Specs 60Hz LS100DX 4 person 5 2 5 10 34 270 lbs 110V 9a LS200DX 4 person 6 5 5 6 29 244 lbs 110V 9a LS350DX 5 person 6 0 6 9 34 351 LBS 110V 9a LS400DX 5 person 6 3 6 3...

Page 3: ...ter Cycles 13 Operational Modes 13 SMART WINTER MODE 13 Diagnostic LCD Message 14 component operation Spacomponent operation 15 Fill Up and Start up instructions FILLING THE SpaWITH WATER 16 applying...

Page 4: ...hildren are careful when entering or exiting the spa DON T Allow children to climb onto the spa cover Allow children to have unsupervised access to the spa Avoiding the risk of electrocution Risk of e...

Page 5: ...ore each use of the spa and with the unit operating push the TEST button on the breaker The switch should click over to the Trip position Wait 30 seconds and reset the GFCI breaker by switching it com...

Page 6: ...spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving components Increased side effects of medication The use of drugs alcohol or medication before or duri...

Page 7: ...re with an accurate thermometer Test the water with your hand before entering the spa to be sure it s comfortable SAFETY SIGN A SAFETY SIGN in the owner s package The sign which is required as a condi...

Page 8: ...change clothes or a house entry near the spa is convenient A warmer climate may require shade from the hot sun Consider placement of trees shrubs patio cover or perhaps a gazebo structure to provide...

Page 9: ...rborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area An architect can help to determine if more ventila...

Page 10: ...ment Remove 1 vertical slat and 3 screws on each side of Equipment Access Panel Door Remove 6 screws from Equipment Access Panel Door to remove door Remove screws from Black ABS Door if your spa has v...

Page 11: ...re and attach it to the grounding lug on the power pack located in the equipment compartment 2 Only a licensed electrician may install power to the spa 3 Power supply installation must include a suita...

Page 12: ...HN copper core wire only All wiring must be copper to ensure adequate connections Do not use aluminum wire CAUTION WARNING SHOCK HAZARD No User Serviceable Parts Do not attempt to service any electron...

Page 13: ...t Installation permanently connected The LS600DX requires a 230 volts 32 amp service 2 hot wires a neutral wire and a ground wire When the spa is powered up the heater will provide approximately 4000...

Page 14: ...dicated and should not be shared with any other appliances The power supply must be hard wired into the power pack White Neutral Wire that is connected to Spa Neutral goes HERE 230V Wiring Instruction...

Page 15: ...600DX model firmly press the Jets button once to activate the low speed of the pump and again for the high speed Firmly press the Jets button again to turn off the pump If left running the low or high...

Page 16: ...F To enter the programming screen and toggle between Standard and Economy Mode the following is required 1 Press and hold the Light button for 5 seconds 2 Press the Light button several times until E...

Page 17: ...ater to cool down to a lower temperature Call your dealer or service supplier if problem persists UPL No low level configuration software has been installed into the system Call your dealer or service...

Page 18: ...ill increase or decrease the effects of any jets not in the closed position OZONE GENERATOR The ozone system greatly enhances the quality of the spa water when used to supplement the spa owner s regul...

Page 19: ...uce the amount of water you normally have in the spa To prevent the water from hitting your topside control or flowing over the top edge of the spa Additionally failure to keep enough water in your sp...

Page 20: ...CALCIUM HARDNESS It is important to bring the calcium reading between 100 250 PPM If the reading requires adjustment it should now be corrected If the water is too soft a low reading calcium hardness...

Page 21: ...g it out of the spa requires many turns Rinse cartridge using a garden hose Rotate and separate filter pleats while spraying water to remove all dirt and debris possible Let filter dry and look for ca...

Page 22: ...f the foam inserts This will not be covered under warranty CABINET CARE Little maintenance is required to keep your spa cabinet looking good Spa cabinet product should be cleaned as needed to remove d...

Page 23: ...Water left in the lines might freeze and damage the lines and jets 1 It will be necessary to remove all water from the interior plumbing 2 Remove the floating weir basket and filter cartridge Clean t...

Page 24: ...ove the gray filter ring 4 Check for dirty filter Clean if necessary 5 Make sure all jets are in the open position turn counterclockwise WATER IS TOO HOT 1 Check desired temperature on topside control...

Page 25: ...ck LS600DX 303532 EQUIPMENT PACK LS100DX LS450DX 303046 3 0 hp PUMP LS600DX 230V 2SPD 303001 1 0 hp PUMP LS100DX LS450DX 115V 2SPD 303535 4 BUTTON TOPSIDE CONTROL PANEL 303298 ROUND FILTER WEIR 303299...

Page 26: ...23...

Page 27: ...24...

Page 28: ...Part 303557 14 Rev D 6 14...