Initial start-up

 - When the spa is first powered up the control system begins a 2 minute Startup 

Mode. Different codes will display on the screen. Once Startup Mode completes, the actual tem-

perature is displayed on the screen, 

and the spa will then begin to heat 

and maintain the water temperature 

and the first filter cycle will start. Your 

spa has been designed so that it 

will automatically heat the water to 

the factory set temperature of 100

°

unless you set the spa to a different 

temperature. If power is disconnected 

from the spa, it will automatically 

revert back to the last saved set tem-

perature when power is reapplied.

TEMPERATURE ADJUSTMENT (80°F-104°F/26°c-40°c)

The temperature can only function between 80°F - 104°F / 26°C - 40°C. The last measured 

temperature will constantly display on LCD.
Press the 

Plus

 or 

Minus

 buttons to display the set temperature and indicator . Each time either 

button is pressed again, the set temperature will increase or decrease depending on which button 

is pressed. After five seconds, the LCD will automatically display the current spa temperature.
The heat indicator  lights up when heating. It flashes when there is a request for more heat. Once 

set temperature is reached the indicator shuts off and the low speed of the jet pump turns off after 

30 seconds (if not in filter cycle).

JETS OPERATiON

For LS600DX model, firmly press the 

Jets

 button once to activate the low speed of the pump and 

again for the high speed. Firmly press the 

Jets

 button again to turn off the pump. If left running the 

low or high speed pump will automatically turn off after 1 hour. The "jets" indicator light next to the 

button will blink when jet pump is on low speed and is solid on high speed. For all other models, 

press the 

Jets 

button once to turn on the pump and a second time to turn off the pump.

MULTi cOLOR LED LighT

Press the 

light

 button once to turn on the light, the light indicator next to the button is lit when the 

light is on. Press the button again to turn the light off.  Every time the light is quickly turned off and on 

a new light mode will appear. The sequence is as follows: White, Slow Full color wheel, Amber, Blue, 

Red, Green, Purple, Blue/Green color wheel, Red/Green color wheel and Fast Full color wheel. The 

last light mode used will come back on when the light is turned off for more than 2 seconds.

NOTE: 

If left on, the light will automatically turn off after 4 hours of operation. 

FiLTER cYcLES 

There are two filter cycles: the first cycle (F1) starts right after power up and the second cycle (F2) 

will start 12 hours later. The default duration for the first filter cycle is 1 hour, and 30 minutes for 

the second cycle. Filter cycles (on LS600DX model) only run at low speed. The “Filter” indicator 

 lights up when a filter cycle is on. The duration of each filter cycle can be modified. 

CONTROL PANEL OPERATION

jets   Light

Indicator  Lights

Temp

Minus

Temp

Plus

Summary of Contents for LS100DX

Page 1: ...LS100DX LS600DX OWNER S MANUAL 110V 230V Models...

Page 2: ...h Height Dry Weight Electrical Specs 60Hz LS100DX 4 person 5 2 5 10 34 270 lbs 110V 9a LS200DX 4 person 6 5 5 6 29 244 lbs 110V 9a LS350DX 5 person 6 0 6 9 34 351 LBS 110V 9a LS400DX 5 person 6 3 6 3...

Page 3: ...ter Cycles 13 Operational Modes 13 SMART WINTER MODE 13 Diagnostic LCD Message 14 component operation Spacomponent operation 15 Fill Up and Start up instructions FILLING THE SpaWITH WATER 16 applying...

Page 4: ...hildren are careful when entering or exiting the spa DON T Allow children to climb onto the spa cover Allow children to have unsupervised access to the spa Avoiding the risk of electrocution Risk of e...

Page 5: ...ore each use of the spa and with the unit operating push the TEST button on the breaker The switch should click over to the Trip position Wait 30 seconds and reset the GFCI breaker by switching it com...

Page 6: ...spa Keep any loose articles of clothing or hanging jewelry away from rotating jets or other moving components Increased side effects of medication The use of drugs alcohol or medication before or duri...

Page 7: ...re with an accurate thermometer Test the water with your hand before entering the spa to be sure it s comfortable SAFETY SIGN A SAFETY SIGN in the owner s package The sign which is required as a condi...

Page 8: ...change clothes or a house entry near the spa is convenient A warmer climate may require shade from the hot sun Consider placement of trees shrubs patio cover or perhaps a gazebo structure to provide...

Page 9: ...rborne moisture s effects on exposed wood paper etc in the room To minimize these effects it is best to provide plenty of ventilation to the spa area An architect can help to determine if more ventila...

Page 10: ...ment Remove 1 vertical slat and 3 screws on each side of Equipment Access Panel Door Remove 6 screws from Equipment Access Panel Door to remove door Remove screws from Black ABS Door if your spa has v...

Page 11: ...re and attach it to the grounding lug on the power pack located in the equipment compartment 2 Only a licensed electrician may install power to the spa 3 Power supply installation must include a suita...

Page 12: ...HN copper core wire only All wiring must be copper to ensure adequate connections Do not use aluminum wire CAUTION WARNING SHOCK HAZARD No User Serviceable Parts Do not attempt to service any electron...

Page 13: ...t Installation permanently connected The LS600DX requires a 230 volts 32 amp service 2 hot wires a neutral wire and a ground wire When the spa is powered up the heater will provide approximately 4000...

Page 14: ...dicated and should not be shared with any other appliances The power supply must be hard wired into the power pack White Neutral Wire that is connected to Spa Neutral goes HERE 230V Wiring Instruction...

Page 15: ...600DX model firmly press the Jets button once to activate the low speed of the pump and again for the high speed Firmly press the Jets button again to turn off the pump If left running the low or high...

Page 16: ...F To enter the programming screen and toggle between Standard and Economy Mode the following is required 1 Press and hold the Light button for 5 seconds 2 Press the Light button several times until E...

Page 17: ...ater to cool down to a lower temperature Call your dealer or service supplier if problem persists UPL No low level configuration software has been installed into the system Call your dealer or service...

Page 18: ...ill increase or decrease the effects of any jets not in the closed position OZONE GENERATOR The ozone system greatly enhances the quality of the spa water when used to supplement the spa owner s regul...

Page 19: ...uce the amount of water you normally have in the spa To prevent the water from hitting your topside control or flowing over the top edge of the spa Additionally failure to keep enough water in your sp...

Page 20: ...CALCIUM HARDNESS It is important to bring the calcium reading between 100 250 PPM If the reading requires adjustment it should now be corrected If the water is too soft a low reading calcium hardness...

Page 21: ...g it out of the spa requires many turns Rinse cartridge using a garden hose Rotate and separate filter pleats while spraying water to remove all dirt and debris possible Let filter dry and look for ca...

Page 22: ...f the foam inserts This will not be covered under warranty CABINET CARE Little maintenance is required to keep your spa cabinet looking good Spa cabinet product should be cleaned as needed to remove d...

Page 23: ...Water left in the lines might freeze and damage the lines and jets 1 It will be necessary to remove all water from the interior plumbing 2 Remove the floating weir basket and filter cartridge Clean t...

Page 24: ...ove the gray filter ring 4 Check for dirty filter Clean if necessary 5 Make sure all jets are in the open position turn counterclockwise WATER IS TOO HOT 1 Check desired temperature on topside control...

Page 25: ...ck LS600DX 303532 EQUIPMENT PACK LS100DX LS450DX 303046 3 0 hp PUMP LS600DX 230V 2SPD 303001 1 0 hp PUMP LS100DX LS450DX 115V 2SPD 303535 4 BUTTON TOPSIDE CONTROL PANEL 303298 ROUND FILTER WEIR 303299...

Page 26: ...23...

Page 27: ...24...

Page 28: ...Part 303557 14 Rev D 6 14...

Reviews: