ELECTRICAL REqUIREMENTS
cONFigURiNg SYSTEM
110 VOLT iNSTALLATiON
(cORD cONNEcTED)
Most Spas come with a factory-installed power supply GFCI cord and are to be plugged into a
grounded type 110 volt, 15 ampere receptacle. No other electrical appliance or fixture can be used on
this circuit.
IMPORTANT:
Under
NO
circumstances should an extension cord be used. Use of an extension
cord will seriously degrade the performance of the equipment and can create an electrical hazard.
230 VOLT iNSTALLATiON
(PERMANENTLY cONNEcTED)
The LS600DX requires a 230 volts 32 amp service (2 hot wires, a neutral wire, and a ground wire).
When the spa is powered up, the heater will provide approximately 4000 watts of heat when the
pump is operating in LOW or HIGH speed and the thermostat is calling for heat.
All electrical connections must be made in accordance with the wiring information contained on
the electrical control box cover and the National Electrical Code.
230v Permanently Connected Control box
Install Red, White, black and green #8
wires to the control box terminal block
and connect to a 40 amp Subpanel with a
dedicated gFCI circuit breaker.
SubPanel
green
black
White
Red