![LIFAN Power USA ESI2000i Owner'S Manual Download Page 23](http://html1.mh-extra.com/html/lifan-power-usa/esi2000i/esi2000i_owners-manual_1907701023.webp)
LIFAN Power USA
2205 Industrial Park Road
Van Buren, AR 72956
866-‐471-‐7464
www.lifanpowerusa.com
22
Operation of Generator
HOW TO USE YOUR GENERATOR
(continued)
STOPPING THE GENERATOR:
Refer to Controls and Features section for diagram.
EMERGENCY SHUTDOWN
1.
Press the red “STOP” button on the control panel.
2.
Turn the Ignition Key to “STOP” position or turn the rocker switch to the “OFF”
position.
3.
Turn the Fuel Valve to “OFF” position
NORMAL SHUTDOWN
1.
Unplug all electrical loads or turn the main breaker to the “OFF” position.
2.
In order to stabilize internal equipment temperatures, allow the engine to run
for 3-‐5 minutes under no load.
3.
If the generator will not be in use for more than 7 days, turn the fuel valve to the
“OFF” position and allow the unit to run until the fuel in the carburetor is used
and the engine shuts itself off.
4.
Turn the ignition switch to the “STOP” position and close the Air Inflow Knob.
5.
Allow unit to cool to ambient temperature before storage or transportation.
6.
Always transport the generator with the fuel valve in the “OFF” position. Failure
to do so will result in damage to the engine.
REMOTE SHUTDOWN
1.
Press and hold the “OFF” button (marked with a padlock) on the remote start.