SAFETY PRECAUTIONS

The   following   safety   directions   must   be   carefully   observed   in   order   to   avoid   injury   to
personnel or damage to the environment or to Hydmaster 40 itself. 

Following of these instructions will ensure the safe and uninterrupted use of the machine.

The equipment must not be positioned or use in places where there is a risk 
of explosion or hazardous substances.

The equipment must not get wet and it has to be protected from moisture,
vibration and wind.

Foreign objects must not be inserted or fitted into the equipment.

The machine cannot be covered during the operation

The user must ensure that the appliance is adjusted for the task and that the 
statutory requirements are met.

1. Avoid contamination of the environment

The machine should be kept as clean as possible. When the shaft is pushing the shaft
back to the drum it should be cleaned with a cloth. After the work has been completed
the brushes and the shell of the cleaning shaft must be cleaned, before transporting
the machine into another location

2. General Safety

It is forbidden to stay in immediate contact with the machine while it is operating. 

3. The safety of the operator

The   person/persons   who   are   performing   the   work   should   use   personal   protection:
filtered mouth mask, helmet, earmuffs, goggles, overall, protection shoes and other
necessary protective equipment that the task at hand requires.

Hydmaster 40 has a strong rotating force. Clothes or hairs can easily get caught in the
brush and cause damage or accidents. The brush has to be placed always in the
ventilation duct before starting the machine. The machine cannot be used when the
brush is outside the ventilation duct. Due to the great rotating force Hydmaster 40 is
recommended to be used by two persons. One who directs the shaft into the duct, and
another who feeds/draws the shaft and controls the rotation of the brush.

4. The safety of the working environment 

Make sure that the lightning, air conditioning, latter and trestles are sufficient. If the
brush   generates   static   electricity   or   sparks   in   the   duct   do   not   use   these   types   of
brushes in the duct if there are any flammable liquids, gases, dust or other sensitive
substances.   Use   antistatic   brushes   and   safety   ground   by   following   the   special
instructions in difficult conditions.

7

THE MACHINE CAN ONLY BE USED WHEN THE POWER SUPPLY IS

RELIABLY EARTH CONNECTED!

Summary of Contents for Hydmaster 40

Page 1: ...aulic motor These instructions should always be available for the personnel who use the machine Please read these instructions before operating the machine Observing and following of these instruction...

Page 2: ...RECTIONS 3 LIFA HYDMASTER 40 4 TECHNICAL INFORMATION 5 CONSTRUCTION AND CONTROL 6 SAFETY PRECAUTIONS 7 OPERATING PRINCIPLES 9 THE USE OF THE MACHINE 10 MAINTENANCE 13 SPARE PARTS 14 PROBLEM SITUATIONS...

Page 3: ...structure functions and safe use 4 No safety functions may be removed or disabled while the machine is being used 5 If the machine has to be installed in a way that stops or impairs the functioning of...

Page 4: ...pylene cover flexible glass fibre rod keeps the shaft in the duct so it is easy to direct in it Hydmaster 40 is designed for ducts that have a diameter from D 315 mm to D 1200 mm 12 4 47 25 inches The...

Page 5: ...changing switch Pneumatically operating and direction changing switches Brush Connection M12 Dimensions Height 1295 mm 51 inches Width 584 mm 23 inches Length 1118 mm 44 inches Weight 93 kg 205 lbs T...

Page 6: ...Motor Drive 3 Safety switch for motor 4 Pneumatic pedal The change of the rotating and operating direction 5 Control of the rotating speed 6 Oil pressure meter 7 Temperature level meter 8 Tool box 6 B...

Page 7: ...ediate contact with the machine while it is operating 3 The safety of the operator The person persons who are performing the work should use personal protection filtered mouth mask helmet earmuffs gog...

Page 8: ...rent has to be switched off when it is not being used 7 Electrical connection Make sure that the voltage supply and the current responds to the information stated in the CE plate and the information i...

Page 9: ...portation the machine has to be tied firmly in order to prevent any damage to the machine or people The machine should be transported used and stored in an upright position Before use make sure that a...

Page 10: ...t the working area is cleared and there are no extra personnel Ensure that all the employees performing the work have adequate protective equipment Make sure that there is enough low pressure in the c...

Page 11: ...mm 6420281010569 300 mm 6420281010583 400 mm 6420281010590 500 mm 6420281010606 600 mm 6420281010613 700 mm 6420281010620 800 mm 6420281010637 900 mm 6420281010644 1000 mm AGGRESSIVE NYLON BRUSH WITH...

Page 12: ...209 Grease Duct chopper Small 350 mm adjustable for ducts 250 500 mm 6420281013010 Y Gear for rectangular ducts 200mm in height 6420281011634 LIFA 3 BRUSH GEAR SET to rotate 3 brushes at same time in...

Page 13: ...long time after it has been unplugged from the electrical network When the voltage has permanently dropped the protective casing can be removed safely Slightly blow compressed air into the frequency...

Page 14: ...e supply mains are attached to an electrical network with protective grounding 230V 50Hz and that the supply mains are in order b Make sure that there is voltage in the electrical network and that a f...

Page 15: ...horized representative of the manufacturer Manufacturer does not accept responsibility for maintenance carried out by a third party A written reclamation form has to be filled out and sent with descri...

Page 16: ...ective EMC 2004 108 EC EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment ROHS 2002 95 EC Sources for harmonized standards EMC EN 55014 E...

Reviews:

Related manuals for Hydmaster 40