Oil change

The first oil change is done in the first regular maintenance (after 1000 operating hours).
After that the oil change has to be done every year. Only Shell TELLUS T 32-hydraulic oil
can be used in the Hydmaster 40 (Technical information). Make sure that there is always
the required amount of oil in the machine unit. The minimum is in the level 50% of the oil
level meter seen, the maximum in the oil level meter of 80%.

SPARE PARTS

When  ordering spare parts,  always  mention the model serial  number and type  of the
machine. The information is in the CE-plate that is situated beside the motor.

PROBLEM SITUATIONS

Possible problem situations and solutions are presented below. If you are not sure on how
to handle problem situations do not hesitate to contact us. Our experts are pleased to 
advice and help you in a way we can get the desired outcome together.

1)

Protective switch for motor does not stay on/does not go on (turn to consruction
and control) 

a) Make   sure   that   the   supply   mains   are   attached   to   an   electrical   network   with

protective grounding (230V/50Hz) and that the supply mains are in order.

b) Make sure that there is voltage in the electrical network and that a fuse has not

burnt.

2) When loaded the machine does not stay on

a. When   the   machine   is   being   used   continuously   for   long   periods   especially   with

largre brushes the motor and the transmission may overheat. If that happens the
automatics cuts off the operaton. The machine is ready automatically when it is
cooled.

b. Make  sure that  there isn’t  other  machines  that  have  a  big powert  consumption

connected to the same electric circuit. The machine should have its own electric
circuit so the machine can get the power it needs.

4)

The cleaning brush does not rotate on steady rotating speed

a.

Make sure the level of the oil is sufficient. The minimum is in the

+30 ºC the maximum in the place of +80 ºC.

b.

Make sure that the machine is placed firmly. If  the machine has

been used transported or stored in uneven place there may be some air in the
hydraulic hoses. Because of this the brush motor may run unevenly for a while.
Once the air has come out of the hose the motor will start to run normally.

14

Summary of Contents for Hydmaster 40

Page 1: ...aulic motor These instructions should always be available for the personnel who use the machine Please read these instructions before operating the machine Observing and following of these instruction...

Page 2: ...RECTIONS 3 LIFA HYDMASTER 40 4 TECHNICAL INFORMATION 5 CONSTRUCTION AND CONTROL 6 SAFETY PRECAUTIONS 7 OPERATING PRINCIPLES 9 THE USE OF THE MACHINE 10 MAINTENANCE 13 SPARE PARTS 14 PROBLEM SITUATIONS...

Page 3: ...structure functions and safe use 4 No safety functions may be removed or disabled while the machine is being used 5 If the machine has to be installed in a way that stops or impairs the functioning of...

Page 4: ...pylene cover flexible glass fibre rod keeps the shaft in the duct so it is easy to direct in it Hydmaster 40 is designed for ducts that have a diameter from D 315 mm to D 1200 mm 12 4 47 25 inches The...

Page 5: ...changing switch Pneumatically operating and direction changing switches Brush Connection M12 Dimensions Height 1295 mm 51 inches Width 584 mm 23 inches Length 1118 mm 44 inches Weight 93 kg 205 lbs T...

Page 6: ...Motor Drive 3 Safety switch for motor 4 Pneumatic pedal The change of the rotating and operating direction 5 Control of the rotating speed 6 Oil pressure meter 7 Temperature level meter 8 Tool box 6 B...

Page 7: ...ediate contact with the machine while it is operating 3 The safety of the operator The person persons who are performing the work should use personal protection filtered mouth mask helmet earmuffs gog...

Page 8: ...rent has to be switched off when it is not being used 7 Electrical connection Make sure that the voltage supply and the current responds to the information stated in the CE plate and the information i...

Page 9: ...portation the machine has to be tied firmly in order to prevent any damage to the machine or people The machine should be transported used and stored in an upright position Before use make sure that a...

Page 10: ...t the working area is cleared and there are no extra personnel Ensure that all the employees performing the work have adequate protective equipment Make sure that there is enough low pressure in the c...

Page 11: ...mm 6420281010569 300 mm 6420281010583 400 mm 6420281010590 500 mm 6420281010606 600 mm 6420281010613 700 mm 6420281010620 800 mm 6420281010637 900 mm 6420281010644 1000 mm AGGRESSIVE NYLON BRUSH WITH...

Page 12: ...209 Grease Duct chopper Small 350 mm adjustable for ducts 250 500 mm 6420281013010 Y Gear for rectangular ducts 200mm in height 6420281011634 LIFA 3 BRUSH GEAR SET to rotate 3 brushes at same time in...

Page 13: ...long time after it has been unplugged from the electrical network When the voltage has permanently dropped the protective casing can be removed safely Slightly blow compressed air into the frequency...

Page 14: ...e supply mains are attached to an electrical network with protective grounding 230V 50Hz and that the supply mains are in order b Make sure that there is voltage in the electrical network and that a f...

Page 15: ...horized representative of the manufacturer Manufacturer does not accept responsibility for maintenance carried out by a third party A written reclamation form has to be filled out and sent with descri...

Page 16: ...ective EMC 2004 108 EC EU Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment ROHS 2002 95 EC Sources for harmonized standards EMC EN 55014 E...

Reviews: