background image

DL-HD2A-RX Owners Manual

3

Important Safety Instructions

 

»

Please completely read and verify you understand all instructions in this manual before operating this equipment. 

 

»

Keep these instructions in a safe, accessible place for future reference. 

 

»

Heed all warnings. 

 

»

Follow all instructions. 

 

»

Do not use this apparatus near water. 

 

»

Clean only with a dry cloth. 

 

»

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) 

that produce heat. 

 

»

Use only accessories specified or recommended by Intelix.

 

»

Explanation of graphical symbols: 

◊  Lightning bolt/flash symbol: the lightning bolt/flash and arrowhead within an equilateral triangle 

symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the 

product enclosure which may be of sufficient magnitude to constitute a risk of shock to a person or 

persons. 

◊  Exclamation point symbol: the exclamation point within an equilateral triangle symbol is intended 

to alert the user to the presence of important operating and maintenance (servicing) instructions 

in the literature accompanying the product. 

 

»

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR 

MOISTURE AND OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD NOT BE PLACED ON THIS APPARATUS.

 

 

»

Use the mains plug to disconnect the apparatus from the mains. 

 

»

THE MAINS PLUG OF THE POWER CORD MUST REMAIN READILY ACCESSIBLE. 

 

»

Do not defeat the safety purpose polarized or grounding-type plug. A polarized plug has two blades with one wider 

than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong 

is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of 

your obsolete outlet. 

Caution! To reduce the risk of electrical shock, grounding of the center pin of this plug must be 

maintained. 

 

»

Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and the 

point where they exit from the apparatus. 

 

»

Do not block the air ventilation openings. Only mount the equipment per Intelix’s instructions. 

 

»

Use only with the cart, stand, table, or rack specified by Intelix or sold with the equipment. When/if a 

cart is used, use caution when moving the cart/equipment combination to avoid injury from tip-over. 

 

»

Unplug this apparatus during lightning storms or when unused for long periods of time. 

 

»

Caution!

 Shock Hazard. Do not open the unit. 

 

»

Refer to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 

power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus 

has been exposed to rain or moisture, does not operate normally, or has been dropped.  

Summary of Contents for DigitaLinx DL-HD2A-RX

Page 1: ...11675 Ridgeline Drive Colorado Springs CO 80921 Rev 200202 Phone 719 260 0061 Toll Free 800 530 8998 Fax 719 260 0075 DL HD2A RX Owners Manual ...

Page 2: ...DL HD2A RX Owners Manual 2 ...

Page 3: ...RATUS Use the mains plug to disconnect the apparatus from the mains THE MAINS PLUG OF THE POWER CORD MUST REMAIN READILY ACCESSIBLE Do not defeat the safety purpose polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provid...

Page 4: ...ransmitter only 8 USB Client 8 Connecting a Display 8 HDMI Output 8 Connecting Audio 8 Audio Input Transmitter only 8 Audio Output 8 Connecting Control 9 RS232 Control Wiring 9 Apply Power 9 Application Diagram 10 RS232 Port CEC Configuration Software Usage 11 Overview 11 Downloading RS232 Port Configuration Software 11 Making a PC Connection 11 Running RS232 Automation Configuration Software 12 S...

Page 5: ...e two 3 5mm analog audio outputs on the DL HD2A RX one that de embeds 2 channel stereo audio from the embedded HDMI stream from the selected HDMI input on the wall plate transmitter and one for the isolated and dedicated analog audio signal from the HDBT 2 0 wall plate as well The DL HD2A RX is ideal for situations where USB must be extended alongside HDMI or VGA for display interactivity for item...

Page 6: ...nal from analog 3 5mm input from the connected HDBaseT 2 0 transmitter 6 USB Device Hub 7 Power LED When ON The receiver is powered on When OFF The receiver is powered off 8 Status LED When BLINKING SLOWLY The receiver is working properly When OFF The receiver is not working properly 9 HDCP LED When ON HDCP protected content is being transmitted When BLINKING Non HDCP protected content is being tr...

Page 7: ... RX receivers HDBaseT input HDBaseT Connection Twisted Pair Wiring Use TIA EIA 568B wiring for Category 6 connection between the transmitter and receiver To ensure proper performance of the DL HD2A RX it is recommended that you use solid core shielded Category 6 F UTP cabling at a minimum Category 5e F UTP may perform well but may not support power over HDBaseT reliably For optimized performance u...

Page 8: ...he connection Connecting A V Sources Connecting USB Peripherals HDMI Input Transmitter only Connecting a Display HDMI Output Connect the display devices to HDMI output on the receiver using an HDMI cable that is less than or equal to 5 meters in length For display devices that are further away it is highly recommended to utilize the HDBaseT output Audio Input Transmitter only Audio Output Note The...

Page 9: ... RX RS232 port can be configured to send stored serial commands from the HDBaseT transmitter so display ON OFF button or can be used for display ON OFF automation when a signal is introduced to the wall plate transmitter when the wall plate is in an OFF state For directions on automation configuration see page 11 RS232 Port Configuration Software Usage Connect the display devices RX RS232 signal t...

Page 10: ...DL HD2A RX Owners Manual 10 Laptop Document Camera Apple TV Audio Source Interactive Projector HDMI CATx AUDIO USB RS232 up to 100m 330 DL HD2 RX NOT INCLUDED Audio Amp Application Diagram ...

Page 11: ...ol port of the DL HD2A RX so the commands can be sent to a connected display or projector to automate power when a video signal is introduced to the system and when the transmitter is in an off state When programming ON OFF commands using this software tool it will also program the DISPLAY on off button operation of the connected HDBaseT 2 0 transmitter as well To connect a PC to the DL HD2A RX RS...

Page 12: ...DL HD2A RX Owners Manual 12 Running RS232 Automation Configuration Software Open the configuration software by double clicking the configuration tool icon The following screen will appear ...

Page 13: ...DL HD2A RX Owners Manual 13 Serial Settings for Wall Plate Transmitter To establish communication with the software select any transmitter under DEVICE TYPES ...

Page 14: ...COM connection has been made Enter in the baud rate for the wall plate transmitter in the BAUD RATE field and click CONNECT The default baud rate for the wall plate transmitter can be found in the transmitters owners manual If you are successfully connected to the unit a green light will appear next the Connect button which will now read DISCONNECT To obtain current RS232 settings you can click th...

Page 15: ...e manufacturers owners manual of the display device If connection was successful the green light next to the Send button will illuminate and pop up window will notify you of the successful connection Once you have entered in the Baud Rate of the display device in the software the wall plate transmitter default baud rate setting will be changed to the same rate setting as well The RS232 configurati...

Page 16: ...light next to the Send button will illuminate and a pop up window will confirm a successful upload If the ASCII based commands require a terminator choose the appropriate terminator from the Set terminator section and then click the Set button If upload is successful a green light next to the Set button will illuminate and a pop up window will confirm a successful upload Note this option is only f...

Page 17: ...n Hex coding check the HEX button next to the Power On command field and then enter the Hex command in the Power On and Power Off field NOTE When entering in HEX formatted commands place a space between each character Prefix and suffix characters are not required i e 0x01 0x 02 01h 02h Correct formatted example is below ...

Page 18: ...he display or projector and trigger the second relay port switch To change the default system timeout choose the desired time from the Delay drop down menu underneath the Power off command field Click the Send button adjacent to the Power off field If upload is successful a green light next to the Send button will illuminate and a pop up window will confirm a successful upload Configuring System T...

Page 19: ...720 x 576 50 720 x 480 60 Standards Compliant with HDMI 2 0 HDCP2 2 USB Supported USB Standard Up to USB 2 0 High Speed up to 190Mbps USB Port Type 4 USB A Audio Supported audio formats HDMI PCM 2 0 LPCM 5 1 LPCM 7 1 Dolby TrueHD DTS HD Mas ter Audio Unbalanced 3 5 mm 2 Channel Stereo Control RS232 Up to 115200 baud rate RS232 Port Type 3 pin phoenix General System Bandwidth 10 2Gbps Transmission ...

Page 20: ...port please call our toll free number at 800 530 8998 or email us at supportlibav libav com www libav com Digitalinx is a brand of 11675 Ridgeline Drive Colorado Springs Colorado 80921 USA Phone 719 260 0061 Fax 719 260 0075 Toll Free 800 530 8998 ...

Reviews: