background image

9

Multi-Protocol Operation 

Analog Operation

This decoder can also be operated on analog layouts or areas of track that are 

analog. The decoder recognizes alternating current (DC) and automatically adapts 

to the analog track voltage. All functions that were set under mfx or DCC for analog 

operation are active (see Digital Operation).

The built-in sound functions come from the factory inactive for analog operation.

Digital Operation

The decoders are multi-protocol decoders. These decoders can be used under the 

following digital protocols: mfx or DCC.

The digital protocol with the most possibilities is the highest order digital protocol. 

The sequence of digital protocols in descending order is:

Priority 1: mfx; Priority 2: DCC; Priority 3: DC

Note:

 Digital protocols can influence each other. For trouble-free operation, we re-

commend deactivating those digital protocols not needed by using CV 50. Deactivate 

unneeded digital protocols at this CV if your controller supports this function. 

If two or more digital protocols are recognized in the track, the decoder automatically 

takes on the highest order digital protocol, example: mfx/DCC; the decoder takes on 

the mfx digital protocol (see previous table).

Note: 

Please note that not all functions are possible in all digital protocols. Several 

settings for functions, which are supposed to be active in analog operation, can be 

done under mfx and DCC.  

Notes on digital operation 

•   The operating instructions for your central unit will give you exact procedures for 

setting the different parameters. 

•   The values set at the factory have been selected for mfx in order to guarantee the 

best possible running characteristics.  

Adjustments may have to be made for other operating systems. 

mfx Protocol

Addresses 

•   No address is required; each decoder is given a one-time, unique identifier (UID).

•   The decoder automatically registers itself on a Central Station or a Mobile Station 

with its UID-identifier.

Programming 

•   The characteristics can be programmed using the graphic screen on the Central 

Station or also partially with the Mobile Station.

•   All of the Configuration Variables (CV) can be read and programmed repeatedly.

•   The programming can be done either on the main track or the programming track.

•   The default settings (factory settings) can be produced repeatedly.

•  14/28 or 126 speed levels can be set. 

As delivered from the factory, the locomotive is programmed for 28 speed levels. If 

your locomotive controller is set for 14 speed levels, then the locomotive must be 

reprogrammed (CV 29, Bit 1).

•   Function mapping: Functions can be assigned to any of the function but-

tons with the help of the 60212 Central Station (with limitations) and with the 

60213/60214/60215 Central Station (See help section in the Central Station).

•  See the CV description for the DCC protocol for additional information.

DCC Protocol

Addresses 

•   Short address – long address – multiple unit address

•   Address range:  

1 – 127 for short address and multiple unit address,  

1 – 10239 for long address 

•   Every address can be programmed manually.

•   Short or long address is selected by means of CV 29 (Bit 5).

•   A multiple unit address that is being used deactivates the standard address. 

Programming

•   The characteristics can be changed repeatedly using the Configuration Variables 

(CV).

•   The CV numbers and the CV values are entered directly.

•   The CVs can be read and programmed repeatedly. (Programming is done on the 

programming track.)

•   The CVs can be programmed in any order desired. (PoM - Programming can be done 

on the main track). PoM is not possible with CVs CV 1, 17, 18, and 29. PoM must be 

supported by your central controller (Please see the description for this unit.).

•   The default settings (factory settings) can be produced repeatedly.

•   14 or 28/126 speed levels can be set.

•   All of the functions can be controlled according to the function mapping (see CV 

description).

•   See the CV description for the DCC protocol for additional information.

We recommend that in general programming should be done on the programming track.  

Summary of Contents for 27632

Page 1: ...Modell der Amtrak Rangierlok 27632...

Page 2: ...2...

Page 3: ...7 Onderhoud en handhaving 18 Schakelbare functies 18 CV 19 Onderdelen 28 Indice del contenuto Pagina Avvertenze per la sicurezza 24 Avvertenze importanti 24 Funzioni 24 Avvertenze per ilfunzionamento...

Page 4: ...eingebauter Multiprotokoll Decoder DC DCC mfx Zum Einsatz mit dem LGB Mehrzugsystem DCC ist das Modell auf Lokadresse 03 programmiert Im Betrieb mit mfx wird die Lok automatisch erkannt Ver nderbare L...

Page 5: ...Keine Adresse erforderlich jeder Decoder erh lt eine einmalige und eindeutige Kennung UID Der Decoder meldet sich an einer Central Station oder Mobile Station mit seiner UID Kennung automatisch an Pr...

Page 6: ...en an den Treibr dern befestigt sind Kuppelstangen abnehmen Mit einen kleinen flachen Schraubendreher den alten Haftreifen entfernen Den alten Haftreifen aus der Rille Nut im Treibrad hebeln Vorsichti...

Page 7: ...1 Analog DC Bit 3 mfx aus an 0 2 0 8 15 Register Belegung Bereich Default 60 Multibahnhofsansage Bit 0 3 Anzahl der Bahnh fe Bit 4 Endansage wechselt die Reihenfolge Bit 5 Lokrichtung wechselt die Re...

Page 8: ...DC 0 24 volts Factory installed multiple protocol decoder DC DCC mfx The model is programmed with locomotive address 03 for use with the LGB Multi Train System DCC The locomotive is automatically reco...

Page 9: ...a Mobile Station with its UID identifier Programming The characteristics can be programmed using the graphic screen on the Central Station or also partially with the Mobile Station All of the Configur...

Page 10: ...side rods from the wheels Use a small flat blade screwdriver to remove the old traction tire Lift the old traction tire from the groove in the driving wheel Carefully push the new traction tire over...

Page 11: ...native Formats Bit 1 Analog DC Bit 3 mfx off on 0 2 0 8 15 Register Assignment Range Default 60 Multi station announcement Bit 0 3 Number of stations Bit 4 Last announcement changes the sequence Bit 5...

Page 12: ...inu DC 0 24 V D codeur multiprotocolaire DC DCC mfx int gr Pour l utilisation avec le syst me multitrain LGB DCC le mod le est programm sur l adresse 03 En mode d exploitation mfx la locomotive est re...

Page 13: ...evront ventuellement tre adapt es Protocole mfx Adressage Aucune adresse n est n cessaire le d codeur re oit toutefois une identification unique et non quivoque UID Avec son UID identification le d co...

Page 14: ...gonales avec lesquelles les tiges d accouplement sont fix es sur les roues motrices Retirer les tiges d accouplement A l aide d un petit tournevis plat retirer le bandage d adh rence us Faire levier p...

Page 15: ...c c Bit 3 Mfx d sactiv activ 0 2 0 8 15 Registres Affectation Domaine Valeur par d faut 60 Annonce en gare multiple Bit 0 3 Nombre des gares Bit 4 Annonce finale modifie l ordre Bit 5 Sens de marche d...

Page 16: ...ars DC 0 24V Fabrieksmatig ingebouwde multiprotocol decoder DC DCC mfx Voor het gebruik met het LGB meertreinen systeem is het model op loc adres 03 ingesteld In het mfx bedrijf wordt de loc automatis...

Page 17: ...g Een adres is niet nodig elke decoder heeft een nmalig en nduidig kenmerk UID De decoder meldt zich vanzelf aan bij het Central Station of Mobile Station met zijn UID kenmerk Programmering De eigensc...

Page 18: ...oppelstangen van de wielen nemen Met een kleine platte schroevendraaier de oude antislipband verwijderen de oude antislipband uit de groef gleuf van het wiel wippen Voorzichtig de nieuwe antislipband...

Page 19: ...3 mfx uit aan 0 2 0 8 15 Register Belegging Bereik Default 60 Multi station omroep Bit 0 3 aantal stations Bit 4 eindstation omroep volgorde wijzigt Bit 5 rijrichting wijzigt de volgorde Bit 6 voorwaa...

Page 20: ...a LGB convencionales corriente continua 0 24 V Decoder multiprotocolo montado en f brica DC DCC mfx Para su uso con el sistema multitren LGB DCC el modelo en miniatura est programado en la direcci n d...

Page 21: ...tificaci n universalmente nica e inequ voca UID El decoder se da de alta autom ticamente en una Central Station o en una Mobile Station con su UID identificaci n Programaci n Las caracter sticas puede...

Page 22: ...t n sujetas a las ruedas motri ces las bielas de acoplamiento Retirar las bielas de acoplamiento Retirar el aro de adherencia antiguo con un destornillador de hoja plana peque o Extraer de la acanalad...

Page 23: ...aci n Rango Valor por defecto 60 Locuci n multiestaci n Bit 0 3 N mero de estaciones Bit 4 La locuci n final cambia el orden Bit 5 El sentido de circulaci n de la locomotora cambia el orden Bit 6 Cons...

Page 24: ...orporato di fabbrica Per l impiego con il sistema LGB per numerosi treni DCC tale modello pro grammato sull indirizzo da locomotiva 03 Nel funzionamento con mfx la locomotiva viene riconosciuta automa...

Page 25: ...automaticamente ad una Central Station oppure Mobile Station con il suo UID identificazione Programmazione Le caratteristiche possono venire programmate tramite la superficie grafica della Central St...

Page 26: ...lle ruote motrici Rimuovere le bielle di accoppiamento Con un piccolo cacciavite piatto rimuovere la vecchia cerchiatura di aderenza Sollevare la vecchia cerchiatura di aderenza fuori dalla scanalatur...

Page 27: ...t 1 DC analogica Bit 3 mfx spento attivo 0 2 0 8 15 Registro Assegnazione Campo Default 60 Annunci di stazione multipli Bit 0 3 numero delle stazioni Bit 4 annuncio finale commuta la sequenza Bit 5 di...

Page 28: ...28 1 2 1 7 8 3 8 2 5 7 4 28...

Page 29: ...29 11 12 10 12 12 10 16 15 10 11 15 14 14 9 12 10 12 15 9 10 16 9 9 12 9...

Page 30: ...30 9 9 9 22 24 23 18 13 27 17 10 21 26 26 25 26 13 13 16 16 16 6 13 13 10 9 9 25 25 20 26 19 19 20 22 27...

Page 31: ...fgef hrt sind k nnen nur im Rahmen einer Reparatur im M rklin Reparatur Service repariert werden Note Several parts are offered unpainted or in another color Parts that are not listed here can only be...

Page 32: ...Gebr M rklin Cie GmbH Stuttgarter Stra e 55 57 73033 G ppingen Germany www lgb de 354439 0621 Sm1Ef nderungen vorbehalten Gebr M rklin Cie GmbH www maerklin com en imprint html...

Page 33: ...Erweiterte Decoderwerte Werkseinstellung 27632...

Page 34: ...nsive knowledge of working with DCC La liste suivante indique la configuration d usine du d codeur pour r f 20580 en ce qui concerne le mappage de fonctions Les param tres peuvent tre modifi s plusieu...

Page 35: ...g30 Event 353 255 Zuweisung31 Trigger 354 0 Zuweisung31 Flags 355 255 Zuweisung31 Event CV Value Description CV Wert Bedeutung 284 68 Zuweisung8 Trigger 285 0 Zuweisung8 Flags 286 178 Zuweisung8 Event...

Page 36: ...t 425 255 Zuweisung55 Trigger 426 0 Zuweisung55 Flags 427 255 Zuweisung55 Event CV Value Description CV Wert Bedeutung 356 255 Zuweisung32 Trigger 357 0 Zuweisung32 Flags 358 255 Zuweisung32 Event 359...

Page 37: ...t 497 255 Zuweisung79 Trigger 498 0 Zuweisung79 Flags 499 255 Zuweisung79 Event CV Value Description CV Wert Bedeutung 428 255 Zuweisung56 Trigger 429 0 Zuweisung56 Flags 430 255 Zuweisung56 Event 431...