73
TROUBLESHOOTING
ENGLISH
Indicator Messages
Clothes have damp
spots after a dry cycle.
Very large load or very small load. Single large item such as a blanket or
comforter.
• If items are too tightly packed or too sparse the sensor may have trouble
reading the dryness level of the load. Use a
Time Dry
cycle for very small
loads.
• Large, bulky items such as blankets or comforters can sometimes wrap
themselves into a tight ball of fabric. The outside layers will dry and
register on the sensors, while the inner core remains damp. When drying
a single bulky item, it may help to pause the cycle once or twice and
rearrange the item to unwrap and expose any damp areas.
• To dry a few remaining damp items from a very large load or a few damp
spots on a large item after a sensor cycle has completed, empty the lint
trap, and then set a
Time Dry
cycle to finish drying the item(s).
Symptoms
Possible Cause & Solution
Flow Sense indicator
(
W
) shows four bars
during the drying cycle
or the display shows
d8O
after drying.
Exhaust system is too long or has too many turns/restrictions.
• Install a shorter or straighter duct run. See the
Installation Instructions
for details.
Partial blockage of the ductwork due to lint buildup or other foreign
object.
• Ductwork should be checked/cleaned immediately. Dryer can be used in
this condition, but drying times will be longer and energy consumption will
increase.
The appliance has detected a restriction in the external dryer venting.
• If exhaust restrictions are sensed by the Flow Sense system, the indicator
will remain on for
2 hours
after the end of the cycle. Opening the door or
pressing the
Power
button will turn off the display.
• This warning light is not a dryer failure and is not covered by the dryer
warranty. Contact a duct cleaning service to set up an appointment to have
your exhaust system cleaned and inspected.
The Flow Sense
indicator (
W
) remains
active after clearing
the restriction in the
venting.
After clearing the restriction, the Flow Sense system requires multiple,
consecutive cycles to determine that the performance value has
improved before the Flow Sense indicator is reset.
• If the Flow Sense indicator remains active for more than five cycles after
the restriction has been cleared, call for service.
Check filter indicator
(
K
) is on during the
drying cycle.
Lint filter not cleaned properly.
• Remove the lint from the filter before every load. With the lint removed,
hold the filter up to a light to see if it is dirty or clogged. If it looks dirty,
follow the cleaning instructions. With some loads that produce high
amounts of lint, it may be necessary to clean the filter during the cycle.
Symptoms
Possible Cause & Solution
global_main.book.book Page 73 Thursday, February 10, 2022 10:27 AM
Summary of Contents for WK22 S6P Series
Page 157: ...Memo global_main book book Page 75 Thursday February 10 2022 10 27 AM ...
Page 158: ...Memo global_main book book Page 76 Thursday February 10 2022 10 27 AM ...
Page 159: ...Memo global_main book book Page 77 Thursday February 10 2022 10 27 AM ...
Page 160: ...Memo global_main book book Page 78 Thursday February 10 2022 10 27 AM ...
Page 161: ...Memo global_main book book Page 79 Thursday February 10 2022 10 27 AM ...
Page 162: ...Memo global_main book book Page 78 Thursday February 10 2022 10 27 AM ...
Page 163: ...Memo global_main book book Page 79 Thursday February 10 2022 10 27 AM ...
Page 164: ...global_main book book Page 75 Thursday February 10 2022 10 27 AM ...