2. Specifications
13
Single CAC
Outdoor Unit
Standard Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit
AUUW366D2
[UU36W UO2]
AUUW366D2
[UU36W UO2]
Indoor unit
ATNH36GNLE2
[UT36 NN2]
ABNW36GM2A0
[UM36 N24]
Capacity
Cooling
Min.~Rated~Max.
kW
4.00 ~ 10.0 ~ 11.0
4.00 ~ 10.0 ~ 11.0
Min.~Rated~Max.
Btu/h
13,600 ~ 34,100 ~ 37,500
13,600 ~ 34,100 ~ 37,500
Heating
Min.~Rated~Max.
kW
4.40 ~ 11.0 ~ 12.1
4.50 ~ 11.2 ~ 12.3
Min.~Rated~Max.
Btu/h
15,000 ~ 37,500 ~ 41,300
15,400 ~ 38,200 ~ 42,000
Power Input
Cooling
Rated
kW
2.82
3.12
Heating
Rated
kW
3.09
3.19
Running Current
Cooling
Rated
A
12.30
13.60
Heating
Rated
A
13.40
13.90
SEER / SCOP
Wh / Wh
5.41 / 3.81
5.11 / 3.81
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating
-
A / A
A / A
Annual Energy Consumption
Cooling / Heating
kWh
648 / 2,800
685 / 2,866
Combination
Outdoor unit
AUUW366D2
[UU36W UO2]
AUUW366D2
[UU36W UO2]
Indoor unit
UVNH36GKLA2
[UV36 NK2]
AJNW36GVLA1
[UJ36 NV3]
Capacity
Cooling
Min.~Rated~Max.
kW
3.80 ~ 9.50 ~ 10.5
4.00 ~ 9.50 ~ 10.50
Min.~Rated~Max.
Btu/h
13,000 ~ 32,400 ~ 35,800
13,600 ~ 32,400 ~ 35,800
Heating
Min.~Rated~Max.
kW
4.20 ~ 10.5 ~ 11.6
4.40 ~ 10.50 ~ 11.50
Min.~Rated~Max.
Btu/h
14,300 ~ 35,800 ~ 39,600
15,000 ~ 35,800 ~ 39,200
Power Input
Cooling
Rated
kW
2.78
2.79
Heating
Rated
kW
3.08
3.27
Running Current
Cooling
Rated
A
12.10
12.10
Heating
Rated
A
13.40
13.40
SEER / SCOP
Wh / Wh
5.11 / 3.81
5.41 / 3.81
Seasonal Energy Label
(A++ to E Scale)
Cooling / Heating
-
A / A
A / A
Annual Energy Consumption
Cooling / Heating
kWh
652 / 2,800
615 / 2,505
Summary of Contents for UU48W U32
Page 1: ...FDF Heat Pump 50Hz 410A 5CSL0 02C Replaces 5CSL0 02B P No MFL67502810 ...
Page 3: ...General Information Single CAC Outdoor Unit FDF 1 Model Line Up 2 Nomenclature ...
Page 41: ...Single CAC Outdoor Unit 3 Dimensions 34 Standard Inverter AUUW85LAE UU85W U74 Chassis code U7 ...
Page 51: ...Single CAC Outdoor Unit 5 Wiring Diagrams 44 Standard Inverter AUUW18GAE UU18W UE4 ...
Page 53: ...Single CAC Outdoor Unit 5 Wiring Diagrams 46 Standard Inverter AUUW366D2 UU36W UO2 ...
Page 55: ...Single CAC Outdoor Unit 5 Wiring Diagrams 48 Standard Inverter AUUW368D2 UU37W UO2 ...
Page 57: ...Single CAC Outdoor Unit 5 Wiring Diagrams 50 Standard Inverter AUUW70LAE UU70W U34 ...
Page 58: ...5 Wiring Diagrams 51 Single CAC Outdoor Unit Standard Inverter AUUW85LAE UU85W U74 ...
Page 126: ...6 Single CAC Outdoor Unit Compact Inverter 3 Dimensions AUUW18GC0 UU18WC UL0 Chassis code UL2 ...
Page 128: ...Single CAC Outdoor Unit 3 Dimensions 8 Compact Inverter AUUW36GC0 UU36WC U40 Chassis code U4 ...
Page 130: ...10 Single CAC Outdoor Unit Compact Inverter 5 Wiring Diagrams Models AUUW18GC0 UU18WC UL0 ...
Page 132: ...Single CAC Outdoor Unit 5 Wiring Diagrams 12 Compact Inverter Models AUUW36GC0 UU36WC U40 ...