Single CAC
Outdoor Unit
6. Piping Diagrams
12
Standard Inverter - Synchro
̰
"Synchro" Quartet
AUUW426D2 [UU42W U32], AUUW486D2 [UU48W U32], AUUW606D2 [UU60W U32]
AUUW428D2 [UU43W U32], AUUW488D2 [UU49W U32], AUUW608D2 [UU61W U32]
AUUW70LAE [UU70W U34], AUUW85LAE [UU85W U74]
Branch kit
(Accessory)
Branch kit
(Accessory)
Service Valve
Gas(
Ø15.88)
Service Valve
Liquid( Ø9.52)
Liquid Piping
ØA
Gas Piping
ØB
Liquid
Piping
ØA
Gas
Piping
ØB
Liquid
Piping
ØA
Gas
Piping
ØB
Liquid
Piping
ØA
Gas
Piping
ØB
M
High
Pressure
Sensor
4 way
Valve
Discharge
Temperature
Thermistor
Suction
Temperature
Thermistor
Accumulator
Inverter
Compressor
Strainer
Strainer
Condenser Out
Temperature
Thermistor
Inlet Air
Temperature
Thermistor
Outdoor Unit
Indoor Unit
Indoor Unit
Indoor Unit
Indoor Unit
Ø9.52
Flare Connection
Ø15.88
Flare Connection
Condensing
Temperature
Thermistor
Electronic
Expansion Valve
Note :
1.The pipes between the indoor units and the branch kits must have
same dimensions as indoor unit connections.
Refrigerant Flow
Cooling
Heating
Heat exchanger
Turbo fa n
Cooling
Heating
M
Thermistor for
suction air
temperature
Thermistor for
Evaporator
outlet temperature
Thermistor for
Evaporator inlet
temperature
Heat exchanger
Turbo fa n
Cooling
Heating
M
Thermistor for
suction air
temperature
Thermistor for
Evaporator
outlet temperature
Thermistor for
Evaporator inlet
temperature
Heat exchanger
Turbo fa n
Cooling
Heating
M
Thermistor for
suction air
temperature
Thermistor for
Evaporator
outlet temperature
Thermistor for
Evaporator inlet
temperature
Heat exchanger
Turbo fa n
Cooling
Heating
M
Thermistor for
suction air
temperature
Thermistor for
Evaporator
outlet temperature
Thermistor for
Evaporator inlet
temperature
9.52
Gas Pipe, B
(mm)
6.35
6.35
12.7
3.5
5
Liquid Pipe, A
(mm)
Indoor Unit
(kW)
Summary of Contents for UU48W U32
Page 1: ...FDF Heat Pump 50Hz 410A 5CSL0 02C Replaces 5CSL0 02B P No MFL67502810 ...
Page 3: ...General Information Single CAC Outdoor Unit FDF 1 Model Line Up 2 Nomenclature ...
Page 41: ...Single CAC Outdoor Unit 3 Dimensions 34 Standard Inverter AUUW85LAE UU85W U74 Chassis code U7 ...
Page 51: ...Single CAC Outdoor Unit 5 Wiring Diagrams 44 Standard Inverter AUUW18GAE UU18W UE4 ...
Page 53: ...Single CAC Outdoor Unit 5 Wiring Diagrams 46 Standard Inverter AUUW366D2 UU36W UO2 ...
Page 55: ...Single CAC Outdoor Unit 5 Wiring Diagrams 48 Standard Inverter AUUW368D2 UU37W UO2 ...
Page 57: ...Single CAC Outdoor Unit 5 Wiring Diagrams 50 Standard Inverter AUUW70LAE UU70W U34 ...
Page 58: ...5 Wiring Diagrams 51 Single CAC Outdoor Unit Standard Inverter AUUW85LAE UU85W U74 ...
Page 126: ...6 Single CAC Outdoor Unit Compact Inverter 3 Dimensions AUUW18GC0 UU18WC UL0 Chassis code UL2 ...
Page 128: ...Single CAC Outdoor Unit 3 Dimensions 8 Compact Inverter AUUW36GC0 UU36WC U40 Chassis code U4 ...
Page 130: ...10 Single CAC Outdoor Unit Compact Inverter 5 Wiring Diagrams Models AUUW18GC0 UU18WC UL0 ...
Page 132: ...Single CAC Outdoor Unit 5 Wiring Diagrams 12 Compact Inverter Models AUUW36GC0 UU36WC U40 ...