10
Product Data
■
3 phase Inverter (12 ~ 16 kW)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound power level is measured on the rated condition in the accordance with ISO 9614 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
Rated sound power level is according to the EN12102-1 under conditions of the EN14825
4. Performances are accordance with EN14511 and reflect ErP testing conditions. Above gives the declared values at rated conditions acc. ErP regulation.
For max. capacities, refer to Performance Data.
• Rated running current : Outdoor Temp. 7°CDB / 6°CWB, LWT 35
℃
5. This product contains Fluorinated greenhouse gases.
* : This values are accordance with EN14825.
Nominal Capacity and Nominal Input
ZHBW128A1
[HM123MR U34]
ZHBW148A1
[HM143MR U34]
ZHBW168A1
[HM163MR U34]
-
-
Outdoor
Temp (°C)
DB / WB
Leaving Water
Temp (°C)
-
Capacity
Cooling
35 / 24
18
kW
12.00
14.00
16.00
7
kW
12.00
14.00
16.00
Heating
7 / 6
35
kW
12.00
14.00
16.00
55
kW
11.00
11.50
12.00
2 / 1
35
kW
11.00
12.00
13.80
Power Input
Cooling
35 / 24
18
kW
2.53
3.26
4.00
7
kW
3.64
4.24
5.16
Heating
7 / 6
35
kW
2.45
2.92
3.40
55
kW
3.79
4.04
4.29
2 / 1
35
kW
3.01
3.31
3.83
EER
Cooling
35 / 24
18
W/W
4.75
4.30
4.00
7
W/W
3.30
3.30
3.10
COP
Heating
7 / 6
35
W/W
4.90
4.80
4.70
55
W/W
2.90
2.85
2.80
2 / 1
35
W/W
3.65
3.63
3.60
SCOP (Low temp. Average Climate)*
4.67
4.62
4.53
SCOP ((Medium temp. Average Climate)*
3.47
3.46
3.45
Rated Water Flow Rate (at LWT 35 ºC)
LPM
34.5
40.3
46.0
Electrical Specifications
ZHBW128A1
[HM123MR U34]
ZHBW148A1
[HM143MR U34]
ZHBW168A1
[HM163MR U34]
Power Supply
V, Ø, Hz
380-415, 3, 50
380-415, 3, 50
380-415, 3, 50
Peak Control Running Current
A
8.0
9.0
10.0
Rated Running Current
Cooling
A
3.7
4.8
5.9
Heating
A
3.6
4.3
5.0
Circuit breaker
A
16
16
16
Wiring Connections
Power Supply Cable
(included Earth, H07RN-F)
mm² x
cores
4.0 x 5C
4.0 x 5C
4.0 x 5C
Technical Specifications
ZHBW128A1
[HM123MR U34]
ZHBW148A1
[HM143MR U34]
ZHBW168A1
[HM163MR U34]
Sound Power Level
Heating
Day Max.
dB(A)
65
66
66
Rated
dB(A)
60
61
61
Low noise
dB(A)
56
57
57
Dimensions
Unit
W × H × D
mm
1,239 × 1,380 × 330
1,239 × 1,380 × 330
1,239 × 1,380 × 330
Packed Unit
W × H × D
mm
1,364 × 1,532 × 461
1,364 × 1,532 × 461
1,364 × 1,532 × 461
Weight
Unit
kg
118.6
118.6
118.6
Packed Unit
kg
133.6
133.6
133.6
Exterior
Color
-
Warm Gray
Warm Gray
Warm Gray
RAL Code
-
RAL 7044
RAL 7044
RAL 7044
Summary of Contents for THERMAV ZHBW056A1
Page 1: ...Air to Water Heat Pump Monobloc R32 50Hz 5BPM5 01C Replaces 5BPM5 01B P No MFL66101126 ...
Page 2: ...THERMA V Monobloc Type General Information Product Data Design and installation ...
Page 3: ...General Information THERMA V Monobloc Type 1 Model Line Up 2 Nomenclature ...
Page 21: ...3 Dimensions 15 THERMA V Monobloc Type Product Data Backup Heater P No TAY37568301 ...