- 88 -
62
Heatsink High error
220-240 V~ heatsink
temperature is over 85°C
1. ODU fan locking
2. Heatsink assembly of PCB assembly 1 condition
abnormal
3. Defect of temperature sensing circuit part defect
of INV PCB(Inverter)
Display
code
Title
Cause of error
Check point & Normal condition
n
Error Diagnosis and Countermeasure Flow Chart
Is installation
condition normal ?
No
Yes
1. Check fan locking
2. Check covering of heat exchanger
3. Check distance between ODU and obstacles
4. Check pipe distortion and abnormality
5. Check service valve is opened
→
Eliminate causes for abnormal condition
Check resistance between NO.19 pin and NO.20 pin
of PFC module
→
Replace PCB(Inverter) if abnormality found
Is assemble condition
of INV PCB(Inverter)
heatsink normal ?
Is PCB(Inverter) temperature
sensing part normal ?
No
No
Yes
Check assemble condition between INV PCB(Inverter)
heatsink and PFC & IPM module
→
Reassemble if
abnormality found
Recheck installation condition
and connection of Heat sink
Yes
<Check the PFCM>
Check Point
1. Check resistance between No.19 pin and NO.20 pin of PCB PFC module
2. Resistance value should be in 7kΩ ±10%.(at 25°C).
Summary of Contents for THERMA V AHBW076A0
Page 7: ... 7 Part 1 General Information 1 Model Names 8 2 External Appearance 8 3 Nomenclature 9 ...
Page 13: ... 13 Part 2 Features Controls 1 List of Function 11 2 Features Controls 12 3 Test Run 34 ...
Page 46: ... 46 Part 5 Trouble Shooting ...
Page 74: ... 74 Vdc AHBW126A0 AHBW146A0 AHBW166A0 P GND ...
Page 86: ... 86 AHBW126A0 AHBW146A0 AHBW166A0 EEPROM ...
Page 98: ...P NO MFL68026801 October 2013 ...