- 37 -
• Function Code 2A
: Miscellaneous setting
- Value #1 of Function Code 2A : determine electric heater and sanitary tank heater on and off.
- Value #2 of Function Code 2A : not used.
- Example : If Value #1 is set as ‘0’, then electric heater and sanitary tank heater are on and off according to con-
trol logic. If Value #1 is set as ‘1’, then electric heater is never turned on and only water heater is on and off ac-
cording to control logic.
• Function Code 2B
: Sanitary water heating timers
Determine following time duration : operation time of sanitary tank heating, stop time of sanitary tank heating, and
delay time of sanitary tank heater operating.
- Value #1 of Function Code 2B : This time duration defines how long time sanitary tank heating can be continued.
- Value #2 of Function Code 2B : This time duration defines how long time sanitary tank heating can be stopped. It
is also regarded as time gap between sanitary tank heating cycle.
- Value #3 of Function Code 2B : This time duration defines how long time sanitary tank heater will not be turned
on in sanitary water heating operation.
- Example of timing chart :
Sanitary tank
heating is enabled
Sanitary tank heater
is enabled
Sanitary tank
heating is required
Sanitary tank
heating operation
Sanitary tank
heater operation
Time
2B.03
2B.03
2B.01
2B.01
2B.02
2B.02
2B.02
Summary of Contents for THERMA V AHBW076A0
Page 7: ... 7 Part 1 General Information 1 Model Names 8 2 External Appearance 8 3 Nomenclature 9 ...
Page 13: ... 13 Part 2 Features Controls 1 List of Function 11 2 Features Controls 12 3 Test Run 34 ...
Page 46: ... 46 Part 5 Trouble Shooting ...
Page 74: ... 74 Vdc AHBW126A0 AHBW146A0 AHBW166A0 P GND ...
Page 86: ... 86 AHBW126A0 AHBW146A0 AHBW166A0 EEPROM ...
Page 98: ...P NO MFL68026801 October 2013 ...