Accessories Installation
30
Air-to-Water Heat Pump
Wall
Side
Wall
Side
Wall
Side
Wall
Side
<Connecting order>
<Separating order>
3. Please fix remote controller upper part into
the setup board attached to the surface of
the wall, as the picture below, and then,
connect with setup board by pressing lower
part.
- Please connect not to make a gap at the
remote controller and setup board’s upper and
lower, right and left part.
When separating remote controller from
setup board, as the picture below, after
inserting into the lower separating hole
using screw driver and then, spinning
clockwise, remote controller is separated.
- There are two separating holes. Please
individually separate one at a time.
- Please be careful not to damage the inside
components when separating.
4. Please connect Main PCB and remote controller using connection cable.
5. Please use extension cable if the distance between wired remote controller and unit is
more than 10m.
Connecting cable
Please check if connector
is normally connected.
PCB assembly
1 of unit side
ZDWHU
ZDWHU
WHPS
WHPS
RSHU
RSHU
KHDWLQJ
KHDWLQJ
PRGH
PRGH
ZDWHU
ZDWHU
WHPS
WHPS
RSHU
RSHU
KHDWLQJ
KHDWLQJ
PRGH
PRGH
When installing the wired remote controller, do not bury it in the wall.
(It can cause damage in the temperature sensor.)
Do not install the cable to be 50m or above. (It can cause communication error.)
• When installing the extension cable, check the connecting direction of the connector of the
remote controller side and the product side for correct installation.
• If you install the extension cable in the opposite direction, the connector will not be connected.
• Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above.
CAUTION